Immunofluorescence measurement in a flow cytometer using low-power helium-neon laser excitation
- PMID: 6363017
- DOI: 10.1002/cyto.990040314
Immunofluorescence measurement in a flow cytometer using low-power helium-neon laser excitation
Abstract
Helium-neon lasers are economical and efficient light sources; their utility in flow cytometry to date has been limited by the lack of fluorescent probes that can be excited at 633 nm. Allophycocyanin (APC), a highly fluorescent phycobiliprotein, can be used as an antibody label and has spectral characteristics suitable for use with He-Ne lasers; we undertook to resolve whether a low-power (7 mW) He-Ne laser could provide sufficient excitation to permit flow cytometric detection of APC-labeled antibodies on cell surfaces. We made an APC conjugate of monoclonal antibody 4F2, which reacts with an antigen abundant on the surfaces of activated human T-lymphocytes; APC-4F2 was used to stain blood mononuclear cells that had been cultured with and without phytohemagglutinin (PHA). Cells so stained were examined in a flow cytometer with orthogonal illumination at 633 nm from a 7 mW He-Ne laser; antibody-bearing cells were detectable by fluorescence emission above 665 nm. Cells from the same cultures were stained with fluorescein-labeled 4F2 antibody and examined in a flow cytometer with argon ion laser excitation at 488 nm. Percentages of antibody-bearing cells determined from APC fluorescence and from fluorescein fluorescence were in good agreement. It thus appears that He-Ne lasers and APC-antibodies are usable for immunofluorescence measurements; the sensitivity attainable with this technique remains to be determined.
Similar articles
-
Comparison of helium-neon and dye lasers for the excitation of allophycocyanin.Cytometry. 1987 Jan;8(1):96-100. doi: 10.1002/cyto.990080114. Cytometry. 1987. PMID: 3542436
-
Visible diode lasers can be used for flow cytometric immunofluorescence and DNA analysis.Cytometry. 1994 Mar 1;15(3):267-71. doi: 10.1002/cyto.990150312. Cytometry. 1994. PMID: 8187585
-
Flow cytometric immunofluorescence and DNA analysis: using a 1.5 mW helium-neon laser (544 nm).Cytometry. 1995 Oct 1;21(2):211-7. doi: 10.1002/cyto.990210214. Cytometry. 1995. PMID: 8582242
-
Detection of cytokine receptors by high-sensitivity immunofluorescence/flow cytometry.Immunobiology. 1992 Aug;185(2-4):350-65. doi: 10.1016/S0171-2985(11)80652-2. Immunobiology. 1992. PMID: 1452210 Review.
-
Immunofluorescence: quantitative considerations.Acta Histochem Suppl. 1988;35:77-83. Acta Histochem Suppl. 1988. PMID: 3138723 Review.
Cited by
-
A brilliant new addition to the fluorescent probe toolbox.Cytometry A. 2012 Jun;81(6):445-6. doi: 10.1002/cyto.a.22036. Epub 2012 Apr 6. Cytometry A. 2012. PMID: 22488984 Free PMC article. No abstract available.
-
Purification and fractionation of phycobiliproteins from Arthrospira platensis and Corallina officinalis with evaluating their biological activities.Sci Rep. 2023 Aug 31;13(1):14270. doi: 10.1038/s41598-023-41001-y. Sci Rep. 2023. PMID: 37652963 Free PMC article.
-
An overview: biomolecules from microalgae for animal feed and aquaculture.J Biol Res (Thessalon). 2014 May 19;21(1):6. doi: 10.1186/2241-5793-21-6. eCollection 2014 Dec. J Biol Res (Thessalon). 2014. PMID: 25984489 Free PMC article. Review.
-
A deep profiler's guide to cytometry.Trends Immunol. 2012 Jul;33(7):323-32. doi: 10.1016/j.it.2012.02.010. Epub 2012 Apr 2. Trends Immunol. 2012. PMID: 22476049 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources