Antimicrobial susceptibility testing (AST): a review of changing trends, quality control guidelines, test accuracy, and recommendation for the testing of beta-lactam drugs
- PMID: 6368105
- DOI: 10.1016/0732-8893(83)90028-7
Antimicrobial susceptibility testing (AST): a review of changing trends, quality control guidelines, test accuracy, and recommendation for the testing of beta-lactam drugs
Abstract
The review that follows presents the changing trends in antimicrobial susceptibility testing observed from the author's clinical laboratory experience and the proficiency testing surveys of the College of American Pathologists (CAP). The CAP Microbiology Surveys show a clear trend toward standardized test methods of the National Committee for Clinical Laboratory Standard (NCCLS) and greater compliance with specified methods' technical steps. This has favorably influenced the laboratory performance on proficiency challenges where a 3-5% improvement has been noted over the last 5 years for the disk tests (overall acceptable rate of 95.2% in 1981). A concurrent increase in dilution test use, mainly broth microdilution methods, has resulted in greater than 25% of larger hospital laboratories reporting results as MICs (overall acceptable or good performance = 98%). Automated systems use also continues to increase, with user performance being monitored at an acceptable level. Quality control frequency may be reduced to once weekly without compromising test accuracy or patient care, but only after adequate daily or concurrent QC performance has been documented. Most methods continue to have problems in testing enterococci, methicillin-resistant staphylococci, and the class-disk concept appears to be less applicable. Recommendations are made for the testing of the newer semisynthetic penicillins and cephalosporins based on their spectrum comparability and cross-resistance studies with bacteria possessing known susceptibility or resistance mechanisms. The concept of "spectrum-class" is introduced with peer drugs within classes. The general trends and quality of antimicrobial susceptibility tests seem outstanding and point toward continued excellent intra- and interlaboratory reproducibility at the national level, primarily due to the efforts of the inspection and accreditation agencies, CAP, CDC, and other concerned professional groups.
Similar articles
-
Method preferences and test accuracy of antimicrobial susceptibility testing: updates from the College of Amercian Pathologists Microbiology Surveys Program.Arch Pathol Lab Med. 2001 Oct;125(10):1285-9. doi: 10.5858/2001-125-1285-MPATAO. Arch Pathol Lab Med. 2001. PMID: 11570902
-
Ability of laboratories to detect emerging antimicrobial resistance: proficiency testing and quality control results from the World Health Organization's external quality assurance system for antimicrobial susceptibility testing.J Clin Microbiol. 2001 Jan;39(1):241-50. doi: 10.1128/JCM.39.1.241-250.2001. J Clin Microbiol. 2001. PMID: 11136778 Free PMC article.
-
The World Health Organization's External Quality Assurance System Proficiency Testing Program has improved the accuracy of antimicrobial susceptibility testing and reporting among participating laboratories using NCCLS methods.J Clin Microbiol. 2003 Jun;41(6):2372-7. doi: 10.1128/JCM.41.6.2372-2377.2003. J Clin Microbiol. 2003. PMID: 12791851 Free PMC article.
-
The identification and antimicrobial susceptibility testing of Neisseria gonorrhoeae, 1980-1987. Results from the College of American Pathologists Microbiology Surveys Program.Arch Pathol Lab Med. 1988 May;112(5):485-8. Arch Pathol Lab Med. 1988. PMID: 3128961 Review.
-
Antimicrobial susceptibility testing of anaerobic bacteria: review and update on the role of the National Committee for Clinical Laboratory Standards.Rev Infect Dis. 1990 Jan-Feb;12 Suppl 2:S218-22. doi: 10.1093/clinids/12.supplement_2.s218. Rev Infect Dis. 1990. PMID: 2406873 Review.
Cited by
-
Effect of the source of Mueller-Hinton agar and resistance frequency on the detection of methicillin-resistant Staphylococcus aureus.J Clin Microbiol. 1985 Feb;21(2):205-10. doi: 10.1128/jcm.21.2.205-210.1985. J Clin Microbiol. 1985. PMID: 3844408 Free PMC article.
-
Accuracy and reproducibility of the AutoMicrobic System Gram-Negative General Susceptibility-Plus Card for testing selected challenge organisms.J Clin Microbiol. 1985 Sep;22(3):355-60. doi: 10.1128/jcm.22.3.355-360.1985. J Clin Microbiol. 1985. PMID: 3930559 Free PMC article.
-
Tests for bactericidal effects of antimicrobial agents: technical performance and clinical relevance.Clin Microbiol Rev. 1992 Oct;5(4):420-32. doi: 10.1128/CMR.5.4.420. Clin Microbiol Rev. 1992. PMID: 1423219 Free PMC article. Review.
-
Comparison of BIOGRAM and commercial microdilution antimicrobial susceptibility test systems.J Clin Microbiol. 1987 Feb;25(2):301-4. doi: 10.1128/jcm.25.2.301-304.1987. J Clin Microbiol. 1987. PMID: 3818926 Free PMC article.
-
How the microbiology laboratory can improve antimicrobial therapy.Bull N Y Acad Med. 1984 May;60(4):314-26. Bull N Y Acad Med. 1984. PMID: 6372912 Free PMC article. No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous