Effect of exogenous surfactant on total respiratory system compliance
- PMID: 6372707
- PMCID: PMC1628669
- DOI: 10.1136/adc.59.4.369
Effect of exogenous surfactant on total respiratory system compliance
Abstract
We measured total respiratory system compliance (Crs) before and after instilling 25 mg artificial surfactant in 1 ml saline down the endotracheal tube of preterm babies requiring resuscitation at birth, and compared results with data from 6 similar babies receiving saline only. Surfactant did not produce a significant improvement in Crs.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources