Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1984 Jul-Aug;7(4):331-7.
doi: 10.2337/diacare.7.4.331.

Continuous subcutaneous insulin infusion (Mill-Hill Infuser) versus multiple injections (Medi-Jector) in the treatment of insulin-dependent diabetes mellitus and the effect of metabolic control on microangiopathy

Clinical Trial

Continuous subcutaneous insulin infusion (Mill-Hill Infuser) versus multiple injections (Medi-Jector) in the treatment of insulin-dependent diabetes mellitus and the effect of metabolic control on microangiopathy

J L Chiasson et al. Diabetes Care. 1984 Jul-Aug.

Abstract

The present study was designed to compare continuous subcutaneous insulin infusion (CSII) using the Mill-Hill Infuser (Muirhead Medical Products Ltd., London, England) with multiple injections (MI) using the Medi-Jector (Derata Corporation, Minneapolis, Minnesota) in the treatment of insulin-dependent diabetes mellitus (IDDM), and to assess the effect of glucose control on diabetes complications. Twelve diabetic subjects were treated 3 mo with CSII and 3 mo with MI (bedtime ultralente and premeal boluses of regular insulin) in a randomized fashion. Prestudy preprandial/postprandial glucose levels were 147-215 mg/dl and improved to 108-138 mg/dl during CSII, and to 115-139 mg/dl during MI with glycosylated hemoglobin of 12.9%, 9.1%, and 8.7%, respectively. This improved glucose control with either CSII or MI was associated with an increase in sural nerve conductivity from 42.9 to 45 m/s and a decrease in proteinuria from 1.9 to 0.5 g/24 h. The 24-h insulin dose consisted of 45 U before the study, 44 U during CSII, and 56 U during MI. After the study, seven patients opted to continue with the Mill-Hill Infuser, and five with the Medi-Jector. We conclude the following: (1) treatment with both the Mill-Hill Infuser and the Medi-Jector was well accepted by the patients and resulted in similar improvement in measured blood glucose and glycosylated hemoglobin; (2) this improved metabolic control was associated with an increased nerve conductivity and a decreased protein excretion; and (3) MI required 20% more insulin than CSII to achieve similar glycemic control.

PubMed Disclaimer

Publication types

LinkOut - more resources