Abstract
Immunoglobulin G (IgG) antibodies to carcinoembryonic antigen (CEA) were labelled with radioactive indium (111In) or iodine (131I) and a comparison made of their value in locating CEA producing tumours. Eleven patients given 111In-anti-CEA had 31 tumours as judged by a combination of all techniques. Of these, 28 were detected by 111In-anti-CEA and 26 by conventional clinical techniques. Five of the patients also received 131I-anti-CEA. These patients had 15 tumour areas. Thirteen were detected by 111In and eight by 131I. 111In also produced a better signal to noise ratio in the scans and thereby showed lesions with greater certainty. In addition, the 111In isotope continued to accumulate in the tumour areas for considerably longer than 131I. Absorbed doses (whole body) were similar for both isotopes. The results show that antibody scanning is greatly improved by using 111In as the radiolabel in place of 131I and should allow the detection of smaller or deeper lesions.
Similar articles
-
Diverse characteristics of 111In labelled anti-CEA monoclonal antibodies for tumour immunoscintigraphy: radiolabelling, biodistribution and imaging studies in mice with human tumour xenografts.Eur J Nucl Med. 1987;12(10):515-21. doi: 10.1007/BF00620477. Eur J Nucl Med. 1987. PMID: 3569340
-
Differences in tumour and normal tissue concentrations of iodine- and indium-labelled monoclonal antibody. II. Biodistribution studies in mice with human tumour xenografts.Eur J Nucl Med. 1985;11(8):300-4. doi: 10.1007/BF00252341. Eur J Nucl Med. 1985. PMID: 4076238
-
A comparison of iodine and indium labelled anti CEA intact antibody, F(ab)2 and Fab fragments by imaging tumour xenografts.Eur J Nucl Med. 1988;13(11):598-604. doi: 10.1007/BF02574776. Eur J Nucl Med. 1988. PMID: 3350036
-
[Possibilities of using monoclonal antibodies to CEA in scintigraphic diagnosis of tumors].Arch Geschwulstforsch. 1985;55(3):207-14. Arch Geschwulstforsch. 1985. PMID: 3896190 Review. German.
-
Cancer imaging with CEA antibodies: historical and current perspectives.Int J Biol Markers. 1992 Jul-Sep;7(3):183-8. Int J Biol Markers. 1992. PMID: 1431343 Review.
Cited by
-
Localisation of gastrointestinal cancer with a 131 I labelled monoclonal antibody to CEA.Br J Cancer. 1986 Feb;53(2):203-10. doi: 10.1038/bjc.1986.36. Br J Cancer. 1986. PMID: 3954942 Free PMC article.
-
The clinical value of imaging with antibody to human chorionic gonadotrophin in the detection of residual choriocarcinoma.Br J Cancer. 1987 Jun;55(6):657-60. doi: 10.1038/bjc.1987.134. Br J Cancer. 1987. PMID: 3620310 Free PMC article.
-
A comparative distribution study of 111In-labeled DTPA and TTHA monoclonal antibody conjugates in a choriocarcinoma xenograft model.Eur J Nucl Med. 1986;12(8):394-6. doi: 10.1007/BF00252197. Eur J Nucl Med. 1986. PMID: 3098566
-
Histological correlation of 17 prospective immunoscintigraphies of recurrences of colorectal carcinomas using indium-111-labeled anti-cea and(or) 19-9 monoclonal antibodies.Eur J Nucl Med. 1989;15(6):302-6. doi: 10.1007/BF00435470. Eur J Nucl Med. 1989. PMID: 2670570
-
Current status of cancer imaging with radiolabeled antibodies.J Cancer Res Clin Oncol. 1987;113(3):203-8. doi: 10.1007/BF00396374. J Cancer Res Clin Oncol. 1987. PMID: 3294845 Free PMC article. Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources