Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1984;62(5):755-61.

Serodiagnosis of pulmonary tuberculosis in Argentina by enzyme-linked immunosorbent assay (ELISA) of IgG antibody to Mycobacterium tuberculosis antigen 5 and tuberculin purified protein derivative

Serodiagnosis of pulmonary tuberculosis in Argentina by enzyme-linked immunosorbent assay (ELISA) of IgG antibody to Mycobacterium tuberculosis antigen 5 and tuberculin purified protein derivative

E A Balestrino et al. Bull World Health Organ. 1984.

Abstract

IgG antibody to Mycobacterium tuberculosis antigen 5 and tuberculin purified protein derivative (PPD) was measured, by enzyme-linked immunosorbent assay (ELISA), in serum samples from 86 patients with active pulmonary tuberculosis and 91 non-tuberculous control subjects from Santa Fé, Argentina. The geometric mean titre for the tuberculosis patients was 74.6 with antigen 5 and 99.5 with PPD. In 91 control subjects the geometric mean titres were 3.6 and 15.6 respectively. Titres were not related to tuberculin reactor status or prior BCG vaccination. At a serum dilution end-point of 1:40, ELISA with antigen 5 had a sensitivity of 81.4% and a specificity of 93.4% for tuberculosis. At 1:40, ELISA with PPD showed a sensitivity of 82.6% and a specificity of 54.9% for tuberculosis. Applied at a serum dilution of 1:40 to a hypothetical model population with a tuberculosis prevalence of 2%, ELISA using antigen 5 would correctly classify 93.2% of persons and ELISA with PPD, 55.5%. At a dilution of 1:80, accuracy is increased to 99.3% with antigen 5 and 83.3% with PPD, but sensitivity decreases to 64.0% with antigen 5 and 72.1% with PPD. Thus, antigen 5 is more accurate than PPD for the diagnosis of tuberculosis using ELISA.

PubMed Disclaimer

References

    1. Tubercle. 1980 Jun;61(2):87-9 - PubMed
    1. Tubercle. 1980 Sep;61(3):145-52 - PubMed
    1. Eur J Respir Dis. 1982 May;63(3):257-62 - PubMed
    1. Int Arch Allergy Appl Immunol. 1983;70(1):25-9 - PubMed
    1. Am Rev Respir Dis. 1982 Dec;126(6):1013-6 - PubMed

Publication types

MeSH terms

LinkOut - more resources