Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1980 Mar;191(3):355-61.
doi: 10.1097/00000658-198003000-00016.

Experimental comparison of the thrombogenicity of fibrin and PTFE flow surfaces

Experimental comparison of the thrombogenicity of fibrin and PTFE flow surfaces

D A Kenny et al. Ann Surg. 1980 Mar.

Abstract

Two types of 4 mm ID prostheses were studied in the carotid arteries of the dog. These were noncrimped polypropylene-supported filamentous velour knitted Dacron (PPSFV) and expanded polytetrafluoroethylene (e-PTFE, Gore-Tex). Thrombus-"Free" Surface TFS) areas and patency rates were determined at the end of the implant periods. One series of implants was subjected to controlled low flow rates for six hours; another was exposed to physiologic flow rates and observed at seven days, 14 days, and 12 weeks. At six hours the filamentous Dacron, preclotted according to a specific regimen utilizating heparin, performed as well as, and possibly better than, e-PTFE. The Gore-Tex developed surface coagulum in an irregular fashion which was related to graft wetting and blood soakage. Seven-day TFS scores and patency rates of the two graft types were comparable at physiologic flow rates. At two weeks, TFS scores and patency rates of the two graft types were comparable at physiologic flow rates. At two weeks, TFS scores and patency rates dropped. This was sufficiently marked in the case of e-PTFE that longer-term implants were not done. However, PPSFV grafts were implanted for 12 weeks, and all grafts examined at that time had closed. It appears that patency of 4 mm ID grafts of this construction will not be reliably attained in the dog carotid artery without the use of platelet-inhibitory drugs until complete healing has occurred.

PubMed Disclaimer

References

    1. Thromb Diath Haemorrh. 1970 Feb 28;23(1):120-8 - PubMed
    1. Surg Gynecol Obstet. 1973 Jan;136(1):12-6 - PubMed
    1. N Engl J Med. 1975 Jan 16;292(3):146-51 - PubMed
    1. Surgery. 1978 Jul;84(1):37-44 - PubMed
    1. Ann Surg. 1978 Nov;188(5):611-22 - PubMed

Publication types

LinkOut - more resources