Complete and partial uterine perforation and embedding following insertion of intrauterine devices. II. Diagnostic methods, prevention, and management
- PMID: 6455610
- DOI: 10.1097/00006254-198108000-00001
Complete and partial uterine perforation and embedding following insertion of intrauterine devices. II. Diagnostic methods, prevention, and management
Abstract
PIP: This paper discusses the various methods used to diagnose uterine perforation caused by an IUD. Radiography, or plain film, has a limited use in the diagnosis of uterine perforation since its usefulness depends on the radiopacity of the particular IUD; if the IUD appears on film, plain film does not allow one to conclude whether the device is in its proper position. Several modifications of plain film have been tried but all methods fall short of their goals. Hysterography permits the best diagnostic assessment since it allows the visualization of the entire uterine cavity so that the position of the IUD is immediately evident in cases of embedding and of perforation. Pelvic pneumography can differentiate between intraperitoneal or extraperitoneal locations of perforated IUDs; it can be enhanced by hysterosalpingography and can be done on an ambulatory basis. Ultrasonography simply determines the presence or absence of an IUD, but has the advantage of accurately demonstrating a concomitant pregnancy; the sonogram is not reliable if the IUD is surrounded by omentum or by loops of bowel; ultrasonography can be advantageously coupled with hysterography. Laparoscopy is still the method most used to diagnose uterine IUD perforation; when removal of the device is advisable laparotomy is usually carried out concomitantly; successful laparoscopy requires a skilled and experienced operator. Hysteroscopy is a new and extremely valuable technique which should not be chosen as a primary procedure because it carries a risk of complications. The best prevention of uterine perforation is a meticulous and well executed insertion technique, done only by an experienced operator and after a careful pelvic examination. Uterine size, consistency and position must be exactly known; IUD insertion is easier during or immediately after menstruation. Perforated IUDs should be removed even if considered innocuous, although this is a matter still debated by the specialists. Spontaneous IUD expulsion must be verified, when not proven, by the same methods used by perforation diagnosis, or by dilatation and curettage. Before deciding on the best method for removal it is necessary to know the type of perforation and the location of the ectopic IUD. Removal of an IUD, whether through the vagina or through hysteroscopic, laparoscopic, laparotomy, or hysterotomy procedures, is never easy. Emergency hysterectomy is done under certain circumstances, such as hemorrhage, while elective hysterectomy requires the presence of additional factors, such as a fibroid uterus. Colpotomy is done only when the IUD is lying in the posterior cul-de-sac.
Similar articles
-
Uterine perforation and embedding by intrauterine device: evaluation by US and hysterography.Radiology. 1985 Dec;157(3):765-70. doi: 10.1148/radiology.157.3.3903858. Radiology. 1985. PMID: 3903858
-
Management of the lost IUD.Afr J Med Med Sci. 1985 Sep-Dec;14(3-4):125-9. Afr J Med Med Sci. 1985. PMID: 3004172
-
Complete and partial uterine perforation and embedding following insertion of intrauterine devices. I. Classification, complications, mechanism, incidence, and missing string.Obstet Gynecol Surv. 1981 Jul;36(7):335-53. doi: 10.1097/00006254-198107000-00001. Obstet Gynecol Surv. 1981. PMID: 7029368 Review.
-
Uterine perforation by copper intrauterine device.Eur J Obstet Gynecol Reprod Biol. 1984 Jun;17(4):257-61. doi: 10.1016/0028-2243(84)90068-6. Eur J Obstet Gynecol Reprod Biol. 1984. PMID: 6378687
-
Perforation of the bladder by the intrauterine device.Obstet Gynecol Surv. 1984 Feb;39(2):59-66. doi: 10.1097/00006254-198402000-00001. Obstet Gynecol Surv. 1984. PMID: 6229704 Review.
Cited by
-
Laparoscopic removal of migrated intrauterine device embedded in intestine.JSLS. 2014 Jul-Sep;18(3):e2014.00122. doi: 10.4293/JSLS.2014.00122. JSLS. 2014. PMID: 25419105 Free PMC article.
-
A 47-Year-Old Woman with Gastric Transmigration of an Intrauterine Contraceptive Device Managed by Laparoscopic Wedge Gastric Resection.Am J Case Rep. 2021 Feb 20;22:e929469. doi: 10.12659/AJCR.929469. Am J Case Rep. 2021. PMID: 33608493 Free PMC article.
-
Case Report: Strangulated intestinal obstruction due to chronic migration of an intrauterine device (IUD): a 30-year latent complication.Front Med (Lausanne). 2025 Jul 7;12:1613116. doi: 10.3389/fmed.2025.1613116. eCollection 2025. Front Med (Lausanne). 2025. PMID: 40692957 Free PMC article.
-
Importance of abdominal X-ray to confirm the position of levonorgestrel-releasing intrauterine system: A case report.World J Clin Cases. 2022 May 26;10(15):4904-4910. doi: 10.12998/wjcc.v10.i15.4904. World J Clin Cases. 2022. PMID: 35801018 Free PMC article.
-
Ectopic intrauterine device in the bladder of a pregnant woman.Case Rep Med. 2010;2010:181032. doi: 10.1155/2010/181032. Epub 2010 Aug 2. Case Rep Med. 2010. PMID: 20811600 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources