Effect of varying size of scleral flap and corneal block on trabeculectomy
- PMID: 6462608
Effect of varying size of scleral flap and corneal block on trabeculectomy
Abstract
Prospectively, 28 eyes of 23 patients undergoing trabeculectomy were divided into two groups. The first group received a large scleral flap (4 mm X 4 mm X 4 mm) and corneal block (3 mm X 3 mm). The second group received a small scleral flap (2 mm X 2 mm X 2 mm) and corneal block (1 mm X 1 mm). No other changes in technique were made. After a mean follow-up of 13 months, there was no significant difference in final intraocular pressure, visual acuity, or complication rates between groups.