Use of continuous monitoring of mixed venous saturation in the coronary care unit
- PMID: 6488916
- DOI: 10.1378/chest.86.5.757
Use of continuous monitoring of mixed venous saturation in the coronary care unit
Abstract
Recent advances in catheter technology that enable continuous measurement of mixed venous oxygen saturation (SvO2) have improved diagnostic and therapeutic capabilities in the critical care setting. The utilization of the Opticath has provided valuable information in the diagnosis and treatment of many critically ill patients in our coronary care unit. In many instances, a change in SvO2 supplied the first indication of a hemodynamic change in the patient. Specific clinical situations in which the Opticath was used are reviewed.
Similar articles
-
Clinical experience with continuous monitoring of mixed venous oxygen saturation in respiratory failure.Chest. 1984 Nov;86(5):748-52. doi: 10.1378/chest.86.5.748. Chest. 1984. PMID: 6488914
-
Continuous monitoring of mixed venous oxygen saturation in critically ill patients.Anesth Analg. 1982 Jun;61(6):513-7. Anesth Analg. 1982. PMID: 7200741
-
Continuous monitoring of mixed venous oxygen saturation in hemodynamically unstable patients.Chest. 1984 Nov;86(5):753-6. doi: 10.1378/chest.86.5.753. Chest. 1984. PMID: 6488915
-
Continuous mixed venous oxygen saturation measurement: a significant advance in hemodynamic monitoring?J Clin Monit. 1985 Oct;1(4):245-58. doi: 10.1007/BF02832818. J Clin Monit. 1985. PMID: 3938481 Review.
-
[The role of mixed venous oxygen saturation in perioperative monitoring and therapy. A critical stock taking].Anasthesiol Intensivmed Notfallmed Schmerzther. 1993 Aug;28(5):269-78. doi: 10.1055/s-2007-998924. Anasthesiol Intensivmed Notfallmed Schmerzther. 1993. PMID: 8373972 Review. German.
Cited by
-
Continuous monitoring of mixed venous oxygen saturation in septic shock.J Clin Monit. 1986 Oct;2(4):237-45. doi: 10.1007/BF02851172. J Clin Monit. 1986. PMID: 3097269
-
Oxygen consumption and mixed venous oxygen saturation monitoring during orthotopic liver transplantation.J Clin Monit. 1992 Jan;8(1):7-11. doi: 10.1007/BF01618080. J Clin Monit. 1992. PMID: 1538256
-
Continuous venous oximetry in surgical patients.Ann Surg. 1986 Mar;203(3):329-33. doi: 10.1097/00000658-198603000-00020. Ann Surg. 1986. PMID: 3954486 Free PMC article.
-
Continuous mixed venous oxygen saturation monitoring during general anesthesia.J Anesth. 1989 Sep 1;3(2):188-93. doi: 10.1007/s0054090030188. J Anesth. 1989. PMID: 15236037
-
Usefulness of central venous oxygen saturation monitoring during cardiopulmonary resuscitation. A comparative case study with end-tidal carbon dioxide monitoring.Intensive Care Med. 1994 Jul;20(6):450-1. doi: 10.1007/BF01710659. Intensive Care Med. 1994. PMID: 7798453
MeSH terms
Substances
LinkOut - more resources
Full Text Sources