Bacteriuria screening by direct bioluminescence assay of ATP
- PMID: 6490851
- PMCID: PMC271402
- DOI: 10.1128/jcm.20.4.644-648.1984
Bacteriuria screening by direct bioluminescence assay of ATP
Abstract
A direct bioluminescence assay for bacteriuria screening is described and compared with the MS-2 system (Abbott Laboratories, Irvine, Tex.) and the chemical strip, Gram smear, and calibrated-loop methods. A total of 973 specimens were tested. Unlike previously described bioluminescence methods, this test measures total ATP in urine without pretreatment of samples to remove somatic ATP. The result was compared with an ATP standard (20 ng/ml). A low result (less than 3% of standard) was interpreted as negative and a high result (greater than 10% of standard) as positive. Samples with intermediate results (38% of total) were incubated at 35 degrees C in thioglycolate broth (1:10). A 2% increase in ATP concentration was interpreted as positive. The sensitivity of this method for detecting greater than 10(5) pathogens per ml was 92.3% and was comparable to those of the MS-2 system (92.7%) and the Gram smear method (90.5%). The chemical strip method was less sensitive (84.0%). The direct bioluminescence method was more sensitive than were the MS-2 system and the Gram smear method for detecting low-level bacteriuria (less than 10(3) to 10(5) organisms per ml), primarily because of associated pyuria. Thioglycolate broth provided a suitable medium for ATP production, and 5% CO2 decreased bacterial ATP synthesis during log-phase growth. The direct bioluminescence assay is rapid, simple, cost-effective, and reliable for bacteriuria screening.
Similar articles
-
Comparison of the Lumac and Monolight systems for detection of bacteriuria by bioluminescence.J Clin Microbiol. 1984 Oct;20(4):797-801. doi: 10.1128/jcm.20.4.797-801.1984. J Clin Microbiol. 1984. PMID: 6490862 Free PMC article.
-
Evaluation of a commercially available semi-automated bioluminescence system for bacteriuria screening.Eur J Clin Microbiol. 1982 Aug;1(4):223-7. doi: 10.1007/BF02019712. Eur J Clin Microbiol. 1982. PMID: 6756912
-
Evaluation of an adenosine 5'-triphosphate assay as a screening method to detect significant bacteriuria.J Clin Microbiol. 1976 Jan;3(1):42-6. doi: 10.1128/jcm.3.1.42-46.1976. J Clin Microbiol. 1976. PMID: 767357 Free PMC article.
-
Automated methods for detection of bacteriuria.Am J Med. 1983 Jul 28;75(1B):71-8. doi: 10.1016/0002-9343(83)90075-x. Am J Med. 1983. PMID: 6192716 Review.
-
Air sampling and ATP bioluminescence for quantitative detection of airborne microbes.Talanta. 2024 Jul 1;274:126025. doi: 10.1016/j.talanta.2024.126025. Epub 2024 Mar 31. Talanta. 2024. PMID: 38574539 Review.
Cited by
-
Rapid screening for bacteriuria in pregnancy.Infection. 1992 Jan-Feb;20(1):9-11. doi: 10.1007/BF01704885. Infection. 1992. PMID: 1563815 Clinical Trial.
-
Evaluation of six screening methods for detecting significant bacteriuria.J Clin Pathol. 1988 Aug;41(8):904-9. doi: 10.1136/jcp.41.8.904. J Clin Pathol. 1988. PMID: 2459164 Free PMC article.
-
Leukocyte esterase-nitrite and bioluminescence assays as urine screens.J Clin Microbiol. 1985 Oct;22(4):531-4. doi: 10.1128/jcm.22.4.531-534.1985. J Clin Microbiol. 1985. PMID: 3935662 Free PMC article.
-
Clinical evaluation of the Lumac bioluminescence method for screening urine specimens.J Clin Microbiol. 1985 Jul;22(1):19-22. doi: 10.1128/jcm.22.1.19-22.1985. J Clin Microbiol. 1985. PMID: 4019739 Free PMC article.
-
FlowUTI: An interactive web-application for optimizing the use of flow cytometry as a screening tool in urinary tract infections.PLoS One. 2022 Nov 8;17(11):e0277340. doi: 10.1371/journal.pone.0277340. eCollection 2022. PLoS One. 2022. PMID: 36346782 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources