Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1984 Oct;20(4):644-8.
doi: 10.1128/jcm.20.4.644-648.1984.

Bacteriuria screening by direct bioluminescence assay of ATP

Bacteriuria screening by direct bioluminescence assay of ATP

R B Schifman et al. J Clin Microbiol. 1984 Oct.

Abstract

A direct bioluminescence assay for bacteriuria screening is described and compared with the MS-2 system (Abbott Laboratories, Irvine, Tex.) and the chemical strip, Gram smear, and calibrated-loop methods. A total of 973 specimens were tested. Unlike previously described bioluminescence methods, this test measures total ATP in urine without pretreatment of samples to remove somatic ATP. The result was compared with an ATP standard (20 ng/ml). A low result (less than 3% of standard) was interpreted as negative and a high result (greater than 10% of standard) as positive. Samples with intermediate results (38% of total) were incubated at 35 degrees C in thioglycolate broth (1:10). A 2% increase in ATP concentration was interpreted as positive. The sensitivity of this method for detecting greater than 10(5) pathogens per ml was 92.3% and was comparable to those of the MS-2 system (92.7%) and the Gram smear method (90.5%). The chemical strip method was less sensitive (84.0%). The direct bioluminescence method was more sensitive than were the MS-2 system and the Gram smear method for detecting low-level bacteriuria (less than 10(3) to 10(5) organisms per ml), primarily because of associated pyuria. Thioglycolate broth provided a suitable medium for ATP production, and 5% CO2 decreased bacterial ATP synthesis during log-phase growth. The direct bioluminescence assay is rapid, simple, cost-effective, and reliable for bacteriuria screening.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Antimicrob Chemother. 1978 Nov;4(6):503-8 - PubMed
    1. N Engl J Med. 1980 Aug 21;303(8):409-15 - PubMed
    1. J Clin Microbiol. 1981 Sep;14(3):342-6 - PubMed
    1. J Clin Microbiol. 1982 Mar;15(3):468-74 - PubMed
    1. J Clin Microbiol. 1982 May;15(5):802-9 - PubMed

LinkOut - more resources