Production of a standard closed fracture in laboratory animal bone
- PMID: 6491805
- DOI: 10.1002/jor.1100020115
Production of a standard closed fracture in laboratory animal bone
Abstract
To develop a technique for the production of a standard closed experimental fracture, a new apparatus was designed and tested on 40 male Sprague-Dawley rats. First, the femur was treated with an intramedullary Steinmann pin. The femoral diaphysis was then fractured by means of a blunt guillotine driven by a dropped weight. Radiographically, this technique resulted in a highly reproducible transverse fracture. There was minimal comminution and minimal angulation of the intramedullary pin. Histologically, there was minimal soft tissue damage. Mechanical testing showed that all fractures healed. Pin removal was accomplished with ease and without disturbance of the healed fracture site. The apparatus is simple to use and inexpensive to build. Through its use, a highly reproducible closed fracture model is established.
Similar articles
-
A new device to produce a standardized experimental fracture in the rat tibia.Saudi Med J. 2007 Jun;28(6):866-71. Saudi Med J. 2007. PMID: 17530101
-
Avoidance of malreduction of proximal femoral shaft fractures with the use of a minimally invasive nail insertion technique (MINIT).J Orthop Trauma. 2008 Jul;22(6):391-8. doi: 10.1097/BOT.0b013e31817713fe. J Orthop Trauma. 2008. PMID: 18594303
-
Production of a standard closed fracture in the rat tibia.J Orthop Trauma. 1994;8(2):111-5. doi: 10.1097/00005131-199404000-00006. J Orthop Trauma. 1994. PMID: 8207566
-
[Ipsilateral fractures of the femoral and tibial diaphyses].Rev Chir Orthop Reparatrice Appar Mot. 1996;82(6):535-40. Rev Chir Orthop Reparatrice Appar Mot. 1996. PMID: 9122525 French.
-
The new unreamed AO nails for the tibia and the femur.Acta Orthop Belg. 1995;61 Suppl 1:204-6. Acta Orthop Belg. 1995. PMID: 8623601
Cited by
-
YAP and TAZ Promote Periosteal Osteoblast Precursor Expansion and Differentiation for Fracture Repair.J Bone Miner Res. 2021 Jan;36(1):143-157. doi: 10.1002/jbmr.4166. Epub 2020 Oct 7. J Bone Miner Res. 2021. PMID: 32835424 Free PMC article.
-
Integrated proteomic and metabolomic profiling of lymph after trauma-induced hypercoagulopathy and antithrombotic therapy.Thromb J. 2024 Jul 10;22(1):59. doi: 10.1186/s12959-024-00634-3. Thromb J. 2024. PMID: 38987792 Free PMC article.
-
Impaired Fracture Healing Caused by Deficiency of the Immunoreceptor Adaptor Protein DAP12.PLoS One. 2015 Jun 1;10(6):e0128210. doi: 10.1371/journal.pone.0128210. eCollection 2015. PLoS One. 2015. PMID: 26030755 Free PMC article.
-
Elcatonin attenuates disuse osteoporosis after fracture fixation of tubular bone in rats.J Orthop Surg Res. 2015 Jul 3;10:103. doi: 10.1186/s13018-015-0246-0. J Orthop Surg Res. 2015. PMID: 26138716 Free PMC article.
-
What Did We Learn About Fracture Pain from Animal Models?J Pain Res. 2022 Sep 13;15:2845-2856. doi: 10.2147/JPR.S361826. eCollection 2022. J Pain Res. 2022. PMID: 36124034 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical