Fine needle aspiration in the diagnosis and management of solid breast lesions
- PMID: 6496857
- DOI: 10.1016/0002-9610(84)90345-3
Fine needle aspiration in the diagnosis and management of solid breast lesions
Abstract
Follow-up data were obtained for 449 fine needle aspirations of solid breast masses from January 1979 through December 1980. The accuracy with which a concordant benign or malignant diagnosis was made was 92 percent. There was a 9.6 percent false-negative rate and a 0.9 percent false-positive rate. Emphasis was placed on the utility of fine-needle aspiration for assessing patients with chronic fibrocystic disease. In 104 cases, patients with a benign cytologic report were followed clinically for 12 months or more. There was a 1.7 percent false-negative rate in this group of patients. We stress that a biopsy should be immediately performed on any worrisome mass, despite the repeatedly negative results of fine needle aspiration. Guidelines for the prevention of false-negative and unsatisfactory cytologic reports have been presented herein. We believe that by careful clinical assessment of the mass, careful performance of the procedure, and close follow-up of the patient, the number of inaccurate fine needle aspirations can be kept at a minimum.
Similar articles
-
Fine-needle aspiration of 697 palpable breast lesions with histopathologic correlation.Surgery. 1997 Oct;122(4):824-8. doi: 10.1016/s0039-6060(97)90093-3. Surgery. 1997. PMID: 9347862
-
Fine-needle aspiration of clinically suspicious palpable breast masses with histopathologic correlation.Am J Surg. 2002 Nov;184(5):410-3. doi: 10.1016/s0002-9610(02)01014-0. Am J Surg. 2002. PMID: 12433603
-
Negative findings on fine-needle aspiration biopsy of solid breast masses: patient management.Am J Surg. 1988 Mar;155(3):387-90. doi: 10.1016/s0002-9610(88)80096-5. Am J Surg. 1988. PMID: 3344899
-
Fine needle aspiration for evaluation of breast masses.Curr Opin Obstet Gynecol. 2007 Feb;19(1):48-55. doi: 10.1097/GCO.0b013e328011f9ae. Curr Opin Obstet Gynecol. 2007. PMID: 17218852 Review.
-
Fine-needle aspiration in the management of breast masses.Pathol Annu. 1989;24 Pt 2:23-62. Pathol Annu. 1989. PMID: 2671883 Review.
Cited by
-
Real-World Diagnostic Accuracy of the On-Site Cytopathology Advance Report (OSCAR) Procedure Performed in a Multidisciplinary One-Stop Breast Clinic.Cancers (Basel). 2023 Oct 13;15(20):4967. doi: 10.3390/cancers15204967. Cancers (Basel). 2023. PMID: 37894334 Free PMC article.
-
Evaluation of aspiration biopsy cytology and combined preoperative tests in the diagnosis of breast cancer.Surg Today. 1995;25(5):404-8. doi: 10.1007/BF00311816. Surg Today. 1995. PMID: 7640467
-
Cost-effectiveness of fine needle biopsy of the breast.Ann Surg. 1986 May;203(5):474-80. doi: 10.1097/00000658-198605000-00005. Ann Surg. 1986. PMID: 3085603 Free PMC article.
-
Diagnosing breast cancer using frozen sections from Tru-cut needle biopsies. Six-year experience with 162 biopsies, with emphasis on outpatient diagnosis of breast carcinoma.Ann Surg. 1985 Dec;202(6):696-701. doi: 10.1097/00000658-198512000-00006. Ann Surg. 1985. PMID: 4073982 Free PMC article.
-
Fibroadenosis of the breast does not require excision biopsy.Postgrad Med J. 1990 Aug;66(778):650-3. doi: 10.1136/pgmj.66.778.650. Postgrad Med J. 1990. PMID: 2217033 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical