Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1984 Dec;44(12 Pt 1):5744-51.

Prolonged binding of a radiolabeled monoclonal antibody (B72.3) used for the in situ radioimmunodetection of human colon carcinoma xenografts

  • PMID: 6498836

Prolonged binding of a radiolabeled monoclonal antibody (B72.3) used for the in situ radioimmunodetection of human colon carcinoma xenografts

D Colcher et al. Cancer Res. 1984 Dec.

Abstract

Monoclonal antibody B72.3 binds to a glycoprotein complex with a molecular weight of 220,000 to 400,000. B72.3 reacts with approximately 50% of human mammary carcinomas and to 80% of the colon carcinomas tested but does not react appreciably with normal mammary tissue, with normal colon, or to a variety of normal adult human tissues tested using immunohistochemical techniques. B72.3 immunoglobulin G was purified and radiolabeled with 125I without significant loss in its reactivity to tumor extracts. The radiolabeled B72.3 immunoglobulin G was shown to efficiently localize human colon carcinoma xenografts in athymic mice. Tumor:tissue ratios of the localized antibody rose over the 7-day period studied, with tumor:liver, tumor:spleen, or tumor:kidney ratios of approximately 18:1 at Day 7 and a tumor:blood ratio of approximately 5:1 at Day 7. Tumor:muscle or tumor:brain ratios rose to over 100:1. The amount of radioactivity in the tumor increased for the first 2 days postinoculation of antibody and stayed constant over a 19-day period of study. Thus, there was no appreciable loss of radioiodine from the tumor over the study interval. No localization was seen in mice bearing a B72.3 antigen-negative human melanoma xenograft or with an isotype-identical control immunoglobulin G in mice bearing colon tumor xenografts. Gamma camera imaging with a pinhole collimator confirmed the ability of the radiolabeled antibody to detect the presence of colon carcinoma xenografts less than 0.5 cm in diameter over a 19-day period. The potential use of this system as a model for radioimmunotherapy will be discussed.

PubMed Disclaimer

LinkOut - more resources