Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1984 Aug;7(4):287-93.
doi: 10.1007/BF03351004.

Simultaneous radioimmunoassay for plasma arginine-vasopressin and oxytocin using DEAE Sephadex A 25 extraction

Simultaneous radioimmunoassay for plasma arginine-vasopressin and oxytocin using DEAE Sephadex A 25 extraction

P Chiodera et al. J Endocrinol Invest. 1984 Aug.

Abstract

A sensitive and specific radioimmunoassay method for simultaneous measurement of plasma arginine vasopressin (AVP) and oxytocin (OT) has been developed utilizing an extraction technique on DEAE Sephadex A25. This procedure resulted in mean recoveries of 70.7% (AVP) and 65.4% (OT) in the peptide range of 5 to 100 pg/4 ml. The sensitivity of the assay is 0.5 pg/tube for AVP and 2 pg/tube for OT. The lower limit of detection for plasma extracts was 1.2 pg AVP/ml and 5 pg OT/ml plasma. Employing this method in normal human non smokers and ad libitum fluid the basal levels (mean +/- SE) of plasma AVP are 3.5 +/- 0.2 pg/ml in males and 4.6 +/- 0.4 pg/ml in females and the basal concentrations of plasma OT are 5.1 +/- 0.3 pg/ml in males and 5.4 +/- 0.3 pg/ml in females. Dehydration and water loading produced significant changes in plasma AVP and OT concentrations and a significant correlation exists between plasma AVP and plasma (r = 0.96, p less than 0.001) and urinary (r = 0.84, p less than 0.01) osmolality, but not between plasma OT concentrations and plasma (r = 0.11, NS) and urinary (r = 0.27, NS) osmolality. These results suggest that a wide range of physiological and pathophysiological changes in plasma AVP and OT can be simultaneously measured by the extraction procedure and the radioimmunoassay described.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Am J Med. 1979 May;66(5):797-803 - PubMed
    1. Am J Obstet Gynecol. 1975 Feb 1;121(3):316-20 - PubMed
    1. J Clin Endocrinol Metab. 1975 Aug;41(2):332-8 - PubMed
    1. Scand J Clin Lab Invest. 1976 Dec;36(8):841-7 - PubMed
    1. J Clin Invest. 1973 Sep;52(9):2340-52 - PubMed

Publication types

LinkOut - more resources