Instability of trochanteric hip fractures following internal fixation. A radiographic comparison of the Richards sliding screw-plate and the McLaughlin nail-plate
- PMID: 6507072
- DOI: 10.3109/17453678408992950
Instability of trochanteric hip fractures following internal fixation. A radiographic comparison of the Richards sliding screw-plate and the McLaughlin nail-plate
Abstract
A comparison was made of the McLaughlin nail plate and the Richards sliding screw-plate techniques for fixation of trochanteric hip fractures. The series included 96 patients in each group. The fractures were followed radiographically for 3 months. Technical failures were encountered in 31 per cent of the McLaughlin fractures and in 8 per cent of the Richards fractures; reoperation was performed in 9 per cent in McLaughlin vs none in the Richards fractures. The main failure was varus displacement in both groups, always combined with lateral cutting of the screw in the Richards fractures, and often combined with failure of the nail-plate junction in McLaughlin fractures. Our study has shown that the sliding screw-plate is superior to the nail plate in both stable and unstable fractures.
Similar articles
-
Unstable trochanteric fractures. A comparative analysis of four methods of internal fixation.Acta Orthop Scand. 1980 Dec;51(6):949-62. doi: 10.3109/17453678008990900. Acta Orthop Scand. 1980. PMID: 7211302
-
Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw.J Orthop Trauma. 1998 May;12(4):241-8. doi: 10.1097/00005131-199805000-00005. J Orthop Trauma. 1998. PMID: 9619458 Clinical Trial.
-
Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.BMC Musculoskelet Disord. 2017 Aug 24;18(1):364. doi: 10.1186/s12891-017-1723-x. BMC Musculoskelet Disord. 2017. PMID: 28836973 Free PMC article.
-
Alternative techniques in trochanteric hip fracture surgery. Clinical and biomechanical studies on the Medoff sliding plate and the Twin hook.Acta Orthop Scand Suppl. 2000 Oct;295:1-31. Acta Orthop Scand Suppl. 2000. PMID: 11116961 Review.
-
Cephalo-medullary nailing versus dynamic hip screw with trochanteric stabilisation plate for the treatment of unstable per-trochanteric hip fractures: a meta-analysis.J Orthop Surg Res. 2021 Jan 11;16(1):47. doi: 10.1186/s13018-020-02193-5. J Orthop Surg Res. 2021. PMID: 33430910 Free PMC article. Review.
Cited by
-
Primary hemiarthroplasty for unstable osteoporotic intertrochanteric fractures in the elderly: A retrospective case series.Indian J Orthop. 2010 Oct;44(4):428-34. doi: 10.4103/0019-5413.67122. Indian J Orthop. 2010. PMID: 20924485 Free PMC article.
-
Acetabular penetration of sliding screw.Arch Orthop Trauma Surg. 1995;114(4):241-2. doi: 10.1007/BF00444273. Arch Orthop Trauma Surg. 1995. PMID: 7662484
Publication types
MeSH terms
LinkOut - more resources