The pattern evoked electroretinogram associated with elevated intraocular pressure
- PMID: 6510723
- DOI: 10.1007/BF02133775
The pattern evoked electroretinogram associated with elevated intraocular pressure
Abstract
Electroretinographic responses to pattern-reversal stimuli (P-ERG) were recorded in eight patients with protracted elevation of intraocular pressure. Pressures of bigger than 30 mm Hg result in marked amplitude reductions in the P-ERG. The observed changes probably reflect the impaired function of retinal ganglion cells caused by decreased oxygen supply.
References
-
- Klin Monbl Augenheilkd. 1975 Feb;166(2):185-9 - PubMed
-
- Arch Ophthalmol. 1982 May;100(5):807-14 - PubMed
-
- Invest Ophthalmol Vis Sci. 1982 Jun;22(6):796-803 - PubMed
-
- Albrecht Von Graefes Arch Ophthalmol. 1952 Mar;152(4-5):527-31 - PubMed
-