High gradient magnetic separation of erythrocytes
- PMID: 656540
- PMCID: PMC1473441
- DOI: 10.1016/S0006-3495(78)85482-4
High gradient magnetic separation of erythrocytes
Abstract
The high gradient magnetic separation technique has been applied to separate paramagnetic erythrocytes from a cell suspension that also contained diamagnetic cells. Paramagnetism was induced in the red blood cells by oxidizing the iron atoms in the cell hemoglobin to the ferric state (methemoglobin). Diamagnetic cells were either untreated erythrocytes, containing oxyferrohemoglobin, or leukocytes in a suspension of mouse spleen cells. Cell suspensions were passed through a column containing 40 micron diameter stainless steel wire in a high magnetic field (33 kG). The paramagnetic cells were retained on the surface of the wire while the diamagnetic cells passed through. Elution of the paramagnetic cells was accomplished by removing the column from the magnet, in effect turning off the field.
Similar articles
-
Magnetic separation techniques: their application to medicine.Mol Cell Biochem. 1985 May;67(1):11-8. doi: 10.1007/BF00220980. Mol Cell Biochem. 1985. PMID: 3894931 Review.
-
High gradient magnetic separation of rosette-forming cells.Cell Biophys. 1981 Jun;3(2):141-53. doi: 10.1007/BF02788130. Cell Biophys. 1981. PMID: 6168377
-
[Effect of a heterogeneous magnetic field on human erythrocytes].Biofizika. 1980 Mar-Apr;25(2):353-5. Biofizika. 1980. PMID: 7370354 Russian.
-
Red blood cell magnetophoresis.Biophys J. 2003 Apr;84(4):2638-45. doi: 10.1016/S0006-3495(03)75069-3. Biophys J. 2003. PMID: 12668472 Free PMC article.
-
Image analysis of bioparticles accumulation and diamagnetic alignment in high-gradient magnetic field.J Biomed Opt. 2005 Sep-Oct;10(5):051702. doi: 10.1117/1.2070127. J Biomed Opt. 2005. PMID: 16292954 Review.
Cited by
-
Development of the "Three-step MACS": a novel strategy for isolating rare cell populations in the absence of known cell surface markers from complex animal tissue.J Biomol Tech. 2012 Jul;23(2):69-77. doi: 10.7171/jbt.12-2302-003. J Biomol Tech. 2012. PMID: 22951961 Free PMC article.
-
Ferritin as a label for high-gradient magnetic separation.Biophys J. 1983 May;42(2):145-50. doi: 10.1016/S0006-3495(83)84380-X. Biophys J. 1983. PMID: 6860772 Free PMC article.
-
Low-Resource Nucleic Acid Extraction Method Enabled by High-Gradient Magnetic Separation.ACS Appl Mater Interfaces. 2020 Mar 18;12(11):12457-12467. doi: 10.1021/acsami.9b21564. Epub 2020 Mar 5. ACS Appl Mater Interfaces. 2020. PMID: 32039572 Free PMC article.
-
Magnetic separation techniques: their application to medicine.Mol Cell Biochem. 1985 May;67(1):11-8. doi: 10.1007/BF00220980. Mol Cell Biochem. 1985. PMID: 3894931 Review.
-
Magnetic sorting of leukocytes.Cell Biophys. 1986 Aug;8(4):287-95. doi: 10.1007/BF02788517. Cell Biophys. 1986. PMID: 2429773
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources