The analysis of errors in orthodontic measurements
- PMID: 6573846
- DOI: 10.1016/0002-9416(83)90322-6
The analysis of errors in orthodontic measurements
Abstract
The sources of error in cephalometric measurement and their analyses are discussed. The importance of distinguishing bias and random errors is emphasized, and methods of control are discussed. Randomization of record measurement is one of the most important methods of avoiding bias, but it is rarely undertaken in cephalometric studies. Random errors are particularly important in the evaluation of individual radiographs, and a measurement that has a high error in relation to its total variability will be of little value in clinical assessment. In serial studies of facial change, the error variance is always a major part of the total variance and thus results have to be interpreted with caution. In cross-sectional studies it is not possible to specify exactly the acceptable limits of random errors, because this will depend on the difference between groups that would be of interest and on the number of cases. The judicious replication of measurements can be important in the control of random errors. In many papers, adequate error evaluation and control is lacking. In these circumstances, the results are of limited value because it is not possible to tell whether an apparent effect is the result of bias in measurement or whether a real effect is being obscured by random errors. It is incumbent on authors to consider how their measurement errors should affect the interpretation of results.
Similar articles
-
Comparison of cephalometric measurements from three radiological clinics.Braz Oral Res. 2006 Apr-Jun;20(2):162-6. doi: 10.1590/s1806-83242006000200013. Braz Oral Res. 2006. PMID: 16878211
-
Effect of training and experience on cephalometric measurement errors on surgical patients.Int J Adult Orthodon Orthognath Surg. 1997;12(3):204-13. Int J Adult Orthodon Orthognath Surg. 1997. PMID: 9511491
-
The effects of differences in landmark identification on the cephalometric measurements in traditional versus digitized cephalometry.Angle Orthod. 2004 Apr;74(2):155-61. doi: 10.1043/0003-3219(2004)074<0155:TEODIL>2.0.CO;2. Angle Orthod. 2004. PMID: 15132440
-
[Facial analysis without cephalometric radiography].Ned Tijdschr Tandheelkd. 2000 Apr;107(4):141-4. Ned Tijdschr Tandheelkd. 2000. PMID: 11382969 Review. Dutch.
-
The importance of determination of jaw position in orthodontic diagnosis and treatment planning for adult patients.Dent Clin North Am. 1997 Jan;41(1):49-66. Dent Clin North Am. 1997. PMID: 9023062 Review.
Cited by
-
Reliability of Acoustic Pharyngometry and Rhinometry Examination in Children and Adolescents.J Oral Maxillofac Res. 2022 Sep 30;13(3):e4. doi: 10.5037/jomr.2022.13304. eCollection 2022 Jul-Sep. J Oral Maxillofac Res. 2022. PMID: 36382012 Free PMC article.
-
Facial soft tissue thickness among skeletal malocclusions: is there a difference?Korean J Orthod. 2012 Feb;42(1):23-31. doi: 10.4041/kjod.2012.42.1.23. Epub 2012 Feb 27. Korean J Orthod. 2012. PMID: 23112928 Free PMC article.
-
External root resorption with the self-ligating Damon system-a retrospective study.Prog Orthod. 2016 Dec;17(1):20. doi: 10.1186/s40510-016-0133-1. Epub 2016 Jul 1. Prog Orthod. 2016. PMID: 27365168 Free PMC article.
-
Three-dimensional densitometric analysis of maxillary sutural changes induced by rapid maxillary expansion.Dentomaxillofac Radiol. 2013;42(2):71798010. doi: 10.1259/dmfr/71798010. Epub 2012 Sep 20. Dentomaxillofac Radiol. 2013. PMID: 22996394 Free PMC article.
-
Radiographic evaluation of orthodontic treatment by means of four different cephalometric superimposition methods.Dental Press J Orthod. 2015 May-Jun;20(3):29-36. doi: 10.1590/2176-9451.20.3.029-036.oar. Dental Press J Orthod. 2015. PMID: 26154453 Free PMC article.
MeSH terms
LinkOut - more resources