Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1978 May;19(5):371-6.
doi: 10.1136/gut.19.5.371.

Comparison of radio-opaque pellets and chromium sesquioxide as inert markers in studies requiring accurate faecal collections

Comparative Study

Comparison of radio-opaque pellets and chromium sesquioxide as inert markers in studies requiring accurate faecal collections

W J Branch et al. Gut. 1978 May.

Abstract

Radio-opaque pellets (ROP) similar to those currently used to measure gastrointestinal transit time have been compared with chromium sesquioxide to assess their suitability for use as inert markers in the gut. Five healthy subjects took both markers with every meal for two separate three week periods while taking metabolically controlled diets. Overall recovery of both markers was satisfactory; ROP 99.7 +/- 0.3% (SD) and chromium 97.8 +/- 1.6% (SD). A comparison of the amount for each marker recovered in 69 separate faecal collection periods of various lengths showed close agreement (R = 0.99) and the tail-off in marker excretion after cessation of ROP and chromium intake was similar, although slightly more prolonged for chromium. The amount of marker retained in the gut was 13.5% greater for chromium at the end of the three week study periods. Both markers proved satisfactory for correcting variations in faecal calcium output. The ROP, however, offer clear advantages over chromium in that they are considerably easier and quicker to measure, the method of measurement using x-rays does not alter the stools and faecal handling is minimised. The precision of ROP measurement is greater and, because of the variety of ROP available, they offer more flexibility for metabolic studies. In addition, stool by stool analysis is possible enabling simultaneous measurement of mean transit time to be made in experimental subjects.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Science. 1952 Dec 5;116(3023):634-5 - PubMed
    1. J Clin Invest. 1960 Jun;39:854-63 - PubMed
    1. Gut. 1964 Jun;5:274-9 - PubMed
    1. J Clin Invest. 1968 Jan;47(1):127-38 - PubMed
    1. Gut. 1971 Aug;12(8):654-60 - PubMed

Publication types