Orthodontic force characteristics of open coil springs
- PMID: 6587783
- DOI: 10.1016/0002-9416(84)90089-7
Orthodontic force characteristics of open coil springs
Abstract
Applications of open coil springs in orthodontic tooth movement are many and varied. Current descriptions of force production by open coil springs are based upon force values produced in series of discrete compression tests. It was the purpose of this study to analyze and compare open-coil-spring force production from continuous load-deflection curves, thereby assisting the clinician in the selection of the ideal spring for a given application. Load-deflection curves were generated for open coil springs of various wire diameters and lumen sizes, as well as four wire alloys from three manufactures. Testing was performed on an Instron test machine using 0.016 inch round and 0.018 by 0.022 inch rectangular arch wires. With a constant lumen size, an increase in wire size produced an increase in force at a given activation. With a constant wire size, an increase in lumen size produced a decrease in force at a given activation. The effect of the arch wire size and shape was not significantly different for the coil springs with the smaller lumen sizes. For the larger lumen sizes, the springs used with the rectangular arch wire manifested a greater linear range than those used with the smaller arch wire. The difference between the load-deflection characteristics of the coil springs from different manufacturers was attributed to the difference in the pitch of the coils.
Similar articles
-
Load-deflection rate measurements of activated open and closed coil springs.Angle Orthod. 1990 Spring;60(1):27-32; discussion 33-4. doi: 10.1043/0003-3219(1990)060<0027:LRMOAO>2.0.CO;2. Angle Orthod. 1990. PMID: 2316900
-
Orthodontic force production by closed coil springs.Am J Orthod. 1978 Oct;74(4):405-9. doi: 10.1016/0002-9416(78)90062-3. Am J Orthod. 1978. PMID: 281143
-
The super-elastic Japanese NiTi alloy wire for use in orthodontics. Part III. Studies on the Japanese NiTi alloy coil springs.Am J Orthod Dentofacial Orthop. 1988 Aug;94(2):89-96. doi: 10.1016/0889-5406(88)90356-3. Am J Orthod Dentofacial Orthop. 1988. PMID: 3165245
-
Force generation by orthodontic coil springs.Angle Orthod. 1993 Summer;63(2):145-8. doi: 10.1043/0003-3219(1993)063<0145:FGBOCS>2.0.CO;2. Angle Orthod. 1993. PMID: 8498703
-
Effects of appliance size, arch wire diameter, and alloy composition on the in vitro force delivery of the quad-helix appliance.Am J Orthod Dentofacial Orthop. 1988 Oct;94(4):311-6. doi: 10.1016/0889-5406(88)90056-x. Am J Orthod Dentofacial Orthop. 1988. PMID: 3052026
Cited by
-
A Speedy Yet Simple Tip to Align Imbricated Anterior Teeth.J Clin Diagn Res. 2017 May;11(5):ZH01-ZH02. doi: 10.7860/JCDR/2017/26291.9858. Epub 2017 May 1. J Clin Diagn Res. 2017. PMID: 28658927 Free PMC article.
-
Open-coil retraction spring.Case Rep Dent. 2011;2011:435709. doi: 10.1155/2011/435709. Epub 2011 Sep 29. Case Rep Dent. 2011. PMID: 22567437 Free PMC article.