Reactivity of low molecular weight material in cellular immune complex assays
- PMID: 6602679
- PMCID: PMC1535839
Reactivity of low molecular weight material in cellular immune complex assays
Abstract
A major difference in molecular size of material reactive in the C1q binding assay and two cellular assays (Raji and L1210) for immune complexes, is reported. Elevated C1q binding of pathological sera was associated with material in the range 7-19S, as determined by Sepharose 6B chromatography of sera from patients with chronic inflammatory and neoplastic lung diseases. By contrast, reactivity of identical sera in the Raji and L1210 assays was linked predominantly with material of molecular size 7S. Dissociation of immune complexes on storage and/or in consequence of the chromatographic procedure was effectively discounted. Furthermore, differential binding of 7S IgG fractions tested at a standard concentration indicated that reactivity in either test was not attributable to non-specific binding of IgG. In a previous study, saturation of FcR (on L1210 and Raji) and C3R (on Raji only) by heat-aggregated IgG failed to distinguish whether binding directly involved these receptors or other cell surface components. In the present investigation, no firm correlations emerged between reactivity in the two tests and possible candidate antibodies reactive with cell surface components such as anti-lymphocyte and anti-nuclear antibodies. It is therefore suggested that low molecular weight binding may be attributable to more than one factor including 7S IgG (immune complex dissociated, or otherwise), autoantibodies, IgG-C3 complexes and possibly very small immune complexes (Ag1, Ab1). The assumption that Raji and L1210 and possibly other cellular assays detect only high molecular weight immune complexes is questionable and the need for further characterization of other reactive material is emphasized.
Similar articles
-
Heterogeneity of circulating immune complexes in chronic lung diseases.J Clin Lab Immunol. 1982 Apr;7(3):155-61. J Clin Lab Immunol. 1982. PMID: 6980284
-
C1q binding activity in the sera of patients with chronic lung diseases.Clin Exp Immunol. 1981 Jul;45(1):18-28. Clin Exp Immunol. 1981. PMID: 6975678 Free PMC article.
-
Influence of immune-complex size and antigen-antibody ratio on immune complex detection with monoclonal rheumatoid factor and C1q.J Clin Lab Immunol. 1984 Oct;15(2):63-8. J Clin Lab Immunol. 1984. PMID: 6335179
-
Immunologic techniques utilized in the diagnosis of occupational lung disease.Clin Chest Med. 1983 Jan;4(1):85-95. Clin Chest Med. 1983. PMID: 6404586 Review.
-
Immunologic techniques utilized in the diagnosis of occupational lung disease.Clin Lab Med. 1984 Sep;4(3):523-38. Clin Lab Med. 1984. PMID: 6434225 Review.
Cited by
-
Evaluation of anti-C1q capture assay for detecting circulating immune complexes and comparison with polyethylene glycol-immunoglobulin G, C1q-binding, and Raji cell methods.J Clin Microbiol. 1987 Aug;25(8):1567-9. doi: 10.1128/jcm.25.8.1567-1569.1987. J Clin Microbiol. 1987. PMID: 2957387 Free PMC article.
-
IgG autoantibodies to C1q do not detectably influence complement activation in vivo and in vitro in systemic lupus erythematosus.Immunol Res. 1992;11(2):91-7. doi: 10.1007/BF02918613. Immunol Res. 1992. PMID: 1431425
-
Fluorescent anti-immunoglobulin G assay of circulating immune complexes extracted with polyethylene glycol.J Clin Microbiol. 1986 Jan;23(1):29-32. doi: 10.1128/jcm.23.1.29-32.1986. J Clin Microbiol. 1986. PMID: 3517044 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous