Brain blood flow measured with intravenous H2(15)O. I. Theory and error analysis
- PMID: 6604139
Brain blood flow measured with intravenous H2(15)O. I. Theory and error analysis
Abstract
The tissue autoradiographic method for the measurement of regional cerebral blood flow (rCBF) in animals was adapted for use with positron emission tomography (PET). Because of the limited spatial resolution of PET, a region of interest will contain a mix of gray and white matter, inhomogeneous in flow and in tracer partition coefficient (lambda). The resultant error in rCBF, however, is less than 4%. Although the tissue autoradiographic method requires a monotonically increasing input function to ensure a unique solution for flow, the PET adaptation does not, because of an additional integration in the operational equation. Simulation showed that the model is accurate in the presence of ischemia or hyperemia of the gray matter. Inaccuracy in timing of the arterial input function will result in large errors in rCBF measurement. Propagation of errors in measurement of tissue activity is largely independent of flow, reflecting the nearly linear flow compared with activity relationship.
Similar articles
-
Brain blood flow measured with intravenous H2(15)O. II. Implementation and validation.J Nucl Med. 1983 Sep;24(9):790-8. J Nucl Med. 1983. PMID: 6604140
-
Positron emission tomographic measurement of cerebral blood flow and permeability-surface area product of water using [15O]water and [11C]butanol.J Cereb Blood Flow Metab. 1987 Oct;7(5):527-42. doi: 10.1038/jcbfm.1987.102. J Cereb Blood Flow Metab. 1987. PMID: 3498732
-
Effect of tissue heterogeneity on the measurement of cerebral blood flow with the equilibrium C15O2 inhalation technique.J Cereb Blood Flow Metab. 1983 Dec;3(4):407-15. doi: 10.1038/jcbfm.1983.66. J Cereb Blood Flow Metab. 1983. PMID: 6415076
-
Precision and accuracy considerations of physiological quantitation in PET.J Cereb Blood Flow Metab. 1991 Mar;11(2):A45-50. doi: 10.1038/jcbfm.1991.36. J Cereb Blood Flow Metab. 1991. PMID: 1997487 Review.
-
H2 clearance measurement of blood flow: a review of technique and polarographic principles.Stroke. 1980 Sep-Oct;11(5):552-64. doi: 10.1161/01.str.11.5.552. Stroke. 1980. PMID: 6999671 Review.
Cited by
-
Thalamic activation during slightly subphysiological glycemia in humans.Diabetes Care. 2012 Dec;35(12):2570-4. doi: 10.2337/dc12-0297. Epub 2012 Aug 13. Diabetes Care. 2012. PMID: 22891254 Free PMC article.
-
Left globus pallidus abnormality in never-medicated patients with schizophrenia.Proc Natl Acad Sci U S A. 1987 Jan;84(2):561-3. doi: 10.1073/pnas.84.2.561. Proc Natl Acad Sci U S A. 1987. PMID: 3467374 Free PMC article.
-
Long term treatment and disease severity change brain responses to levodopa in Parkinson's disease.J Neurol Neurosurg Psychiatry. 2003 Jul;74(7):844-51. doi: 10.1136/jnnp.74.7.844. J Neurol Neurosurg Psychiatry. 2003. PMID: 12810765 Free PMC article. Clinical Trial.
-
Proposal of blood volume-corrected model for quantification of regional cerebral blood flow with H2 15O-PET and its application to AVF.Radiat Med. 2006 May;24(4):260-8. doi: 10.1007/s11604-005-1547-8. Radiat Med. 2006. PMID: 16958399
-
Evaluation of basis function and linear least squares methods for generating parametric blood flow images using 15O-water and Positron Emission Tomography.Mol Imaging Biol. 2005 Jul-Aug;7(4):273-85. doi: 10.1007/s11307-005-0007-2. Mol Imaging Biol. 2005. PMID: 16080023
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources