Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1984 Jan;58(1):91-8.
doi: 10.1210/jcem-58-1-91.

A microassay for 1,25-dihydroxyvitamin D not requiring high performance liquid chromatography: application to clinical studies

A microassay for 1,25-dihydroxyvitamin D not requiring high performance liquid chromatography: application to clinical studies

T A Reinhardt et al. J Clin Endocrinol Metab. 1984 Jan.

Abstract

This report describes a microassay for 1,25-dihydroxyvitamin D [1,25-(OH)2D] in plasma which does not require high performance liquid chromatography. The assay involves rapid extraction and preliminary purification on a C-18 Sep-Pak cartridge, followed by final purification on a silica Sep-Pak using hexane-isopropanol. Quantitation of 1,25-(OH)2D is achieved using a nonequilibrium assay employing 1,25-(OH)2D receptor from calf thymus. The method is sensitive to 1.5 pg/tube, with B50 occurring at 9 pg/tube and a useful assay range of 1.5-40 pg/tube. The intra- and interassay coefficients of variation are 6.5% and 11.5%, respectively, and the method is linear over a wide range of sample dilutions. In addition, this assay measures both 1,25-(OH)2D2 and 1,25-(OH)2D3 with equal affinity. The importance of using an assay with equal affinity for 1,25-(OH)2D2 and 1,25-(OH)2D3 is demonstrated by the findings that 25-hydroxyvitamin D2 (250HD2) constituted 38.9% of the total 25-OHD found in clinical samples (12.6 +/- 0.7 ng/ml 25-OHD2 vs. 20.1 +/- 0.5 ng/ml 25-OHD3; n = 807). Results of this new assay have been compared to those of the assay of Horst et al. (21), which employs Sephadex LH-20 and high performance liquid chromatography sample purification. The correlation coefficient was r2 = 0.96, and the slope was 1.05. Using this new assay, plasma 1,25-(OH)2D concentrations were as follows: normal adults, 37.4 +/- 2.2 pg/ml (n = 22); chronic renal failure, 10.6 +/- 1.5 pg/ml (n = 7); anephrics, undetectable (n = 10); infant cord blood, 22.9 +/- 4.4 pg/ml (n = 7); and hyperparathyroidism, 68.9 +/- 5.0 pg/ml (n = 13). This assay should be particularly useful in pediatric or other studies in which sample size is limited.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources