Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1983 Sep;72(3):289-93.
doi: 10.1097/00006534-198309000-00001.

Correction of lower eyelid ptosis in the anophthalmic orbit: a long-term follow-up

Correction of lower eyelid ptosis in the anophthalmic orbit: a long-term follow-up

W B Nolan 3rd et al. Plast Reconstr Surg. 1983 Sep.

Abstract

We describe a 10-year review of 53 patients having had correction of lower eyelid ptosis using fascia lata sling suspension by the operation first described in 1973. The overall conclusion is that this continues to be a reliable procedure with a low complication rate. Four major changes relating to operative technique that create a better result are as follows: (1) the surgical correction must begin with a prosthesis that is ideal for the socket; (2) the fascial strip is narrower at 2 mm; (3) the lateral orbital rim burr hole is placed higher; and (4) the passage of the fascial strip is facilitated by the use of Wright's needle. The optimal sequence of operative procedures in the anophthalmic orbit syndrome is (1) correction of enophthalmos and superior sulcus depression, (2) correction of lower eyelid ptosis, and (3) correction of upper eyelid ptosis.