Computed tomography, ultrasound, and scintigraphy of the liver in patients with colon or breast carcinoma: a prospective comparison
- PMID: 6611929
- DOI: 10.1148/radiology.149.1.6611929
Computed tomography, ultrasound, and scintigraphy of the liver in patients with colon or breast carcinoma: a prospective comparison
Abstract
A prospective evaluation of computed tomography (CT), ultrasonography (US), and Tc-99m sulfur colloid scintigraphy of the liver was performed in 189 patients who had either colon (n = 129) or breast (n = 60) carcinoma. Imaging was performed with fourth-generation CT scanners, gray-scale or phased array ultrasound scanners, and 37-tube gamma cameras. Studies were evaluated independently and receiver operating characteristic (ROC) curves were constructed. In addition, a standard 2 X 2 matrix analysis was performed. In patients who had all three examinations (n = 122), the matrix analysis showed that CT had a slightly higher sensitivity (0.93) than scintigraphy (0.86) or US (0.82); specificities were 0.88, 0.83, and 0.85, respectively. These differences were not statistically significant. However, ROC curves showed that CT had the highest true-positive ratio at every false-positive ratio, and that US had the lowest. The performance of CT did not differ significantly from that of scintigraphy, but was better than that of US (p less than .05), especially in patients with breast carcinoma. Overall, CT provided the most accurate means for detecting liver metastases from both primary lesions.
Similar articles
-
Detection of hepatic metastases: comparison of EOE-13 computed tomography and scintigraphy.AJR Am J Roentgenol. 1983 Nov;141(5):931-5. doi: 10.2214/ajr.141.5.931. AJR Am J Roentgenol. 1983. PMID: 6312788
-
Diagnosis and screening of small hepatocellular carcinomas. Comparison of radionuclide imaging, ultrasound, computed tomography, hepatic angiography, and alpha 1-fetoprotein assay.Radiology. 1982 Dec;145(3):635-8. doi: 10.1148/radiology.145.3.6183708. Radiology. 1982. PMID: 6183708
-
Radiocolloid liver scintigraphy. A choice and an echo.Radiol Clin North Am. 1980 Aug;18(2):315-9. Radiol Clin North Am. 1980. PMID: 7010413 Review.
-
Liver scintigraphy in colon carcinoma: correlation with modified Duke pathological classification.Radiology. 1982 Nov;145(2):453-5. doi: 10.1148/radiology.145.2.7134452. Radiology. 1982. PMID: 7134452
-
Hepatic scintigraphy.Lab Res Methods Biol Med. 1983;7:277-87. Lab Res Methods Biol Med. 1983. PMID: 6353107 Review. No abstract available.
Cited by
-
[Intraoperative sonography for the detection of occult liver metastases in colorectal cancer].Langenbecks Arch Chir. 1989;374(6):363-9. doi: 10.1007/BF01262816. Langenbecks Arch Chir. 1989. PMID: 2689817 German.
-
Contribution of computed tomography to patients with pancreatic adenocarcinoma.World J Surg. 1984 Dec;8(6):831-8. doi: 10.1007/BF01656022. World J Surg. 1984. PMID: 6516428 No abstract available.
-
Evaluating Estimation Techniques in Medical Imaging Without a Gold Standard: Experimental Validation.Proc SPIE Int Soc Opt Eng. 2003 Feb 15;5034:10.1117/12.480330. doi: 10.1117/12.480330. Proc SPIE Int Soc Opt Eng. 2003. PMID: 26346933 Free PMC article.
-
Ultrasonic patterns observed in hepatic metastases from breast carcinoma: diagnosis and evolution.Gastrointest Radiol. 1989 Winter;14(1):49-54. doi: 10.1007/BF01889154. Gastrointest Radiol. 1989. PMID: 2562948
-
Tc-99m Sulfur Colloid Scintigraphy in Differentiating Fat Sparing from Lymphomatous Involvement of Liver-Old Wine in New Bottle.Indian J Nucl Med. 2022 Oct-Dec;37(4):400-401. doi: 10.4103/ijnm.ijnm_107_22. Epub 2022 Dec 2. Indian J Nucl Med. 2022. PMID: 36817209 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical