New sphenoidal electrode assembly to permit long-term monitoring of the patient's ictal or interictal EEG
- PMID: 66141
- DOI: 10.1016/0013-4694(77)90221-8
New sphenoidal electrode assembly to permit long-term monitoring of the patient's ictal or interictal EEG
Abstract
A new sphenoidal wire electrode is described which greatly increases the clinical and diagnostic usefulness of sphenoidal electrode recordings. These very fine wire electrodes are easy to insert; they are comfortable and acceptable to the patient. In contrast to sphenoidal needle electrodes they expose the patient to no risk should he have a seizure during recording. These electrodes also allow one to extend the recording time to several days, thus increasing the chances of recording a spontaneous seizure, for instance while the patient's EEG is being recorded with a telemetry system. The extended recording time also allows for continuous automatic sampling of the interictal EEG over a period of several days. The quality and the reliability of the EEG record are also enhanced. The new sphenoidal electrodes have been used on over 100 patients and are now being used routinely on suspected temporal lobe epileptics recorded with conventional techniques, while 50 of the patients have also been recorded with a cable-telemetry seizure monitoring system which has captured 65 spontaneous seizures.
Similar articles
-
Seizure moitoring: a new tool in electroencephalography.Electroencephalogr Clin Neurophysiol. 1976 Oct;41(4):422-7. doi: 10.1016/0013-4694(76)90106-1. Electroencephalogr Clin Neurophysiol. 1976. PMID: 60230
-
Long-term ambulatory cassette EEG with sphenoidal recording in complex partial seizures.Epilepsia. 1991 May-Jun;32(3):351-7. doi: 10.1111/j.1528-1157.1991.tb04663.x. Epilepsia. 1991. PMID: 2044498
-
Sphenoidal EEG recording using acupuncture needle electrode in complex partial seizure.Electroencephalogr Clin Neurophysiol. 1991 Aug;79(2):119-26. doi: 10.1016/0013-4694(91)90049-a. Electroencephalogr Clin Neurophysiol. 1991. PMID: 1713825
-
Invasive EEG explorations.Neurophysiol Clin. 2015 Mar;45(1):113-9. doi: 10.1016/j.neucli.2014.11.006. Epub 2015 Jan 15. Neurophysiol Clin. 2015. PMID: 25703438 Review.
-
A new era in electroencephalographic monitoring? Subscalp devices for ultra-long-term recordings.Epilepsia. 2020 Sep;61(9):1805-1817. doi: 10.1111/epi.16630. Epub 2020 Aug 27. Epilepsia. 2020. PMID: 32852091 Review.
Cited by
-
Sphenoidal electrode insertion under local analgesia in children.Childs Nerv Syst. 1992 May;8(3):129-32. doi: 10.1007/BF00298267. Childs Nerv Syst. 1992. PMID: 1611611
-
Functional and morphological abnormalities in temporal lobe epilepsy: a comparison of interictal and ictal EEG, CT, MRI, SPECT and PET.J Neurol. 1987 Aug;234(6):377-84. doi: 10.1007/BF00314081. J Neurol. 1987. PMID: 3498801
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources