Lungco measurement of particles retained in the lungs
- PMID: 6648422
- DOI: 10.5271/sjweh.2421
Lungco measurement of particles retained in the lungs
Abstract
Nearly all metal dusts contain iron, which is one of the most common constituents in steel. Iron has one common ferrimagnetic oxide, magnetite. Although it is considered nontoxic, magnetite can be used as a tracer for more active and pathogenic constituents of inhaled dusts. After the chest area has been magnetized, magnetite produces a weak remanent magnetic field around the body. The field is measured and the amount of dust in the lungs is calculated on the assumption that the composition of lung dust is the same as that of airborne dust. This method has been applied to shipyard and stainless steel welders, to iron and steel workers, to stainless grinders, and to foundry workers. A clear magnetic signal was found for each subject. The maximum amount of lung dust found thus far was 10 g in the lungs of a stainless steel electrode welder. Referents showed signals of 0.5 mg magnetite or less.
Similar articles
-
Measurement of lung-retained contaminants in vivo among workers exposed to metal aerosols.Am Ind Hyg Assoc J. 1981 Mar;42(3):234-8. doi: 10.1080/15298668191419640. Am Ind Hyg Assoc J. 1981. PMID: 7223640
-
Magnetopneumography: a general review.Eur Respir J. 1989 Feb;2(2):149-59. Eur Respir J. 1989. PMID: 2649394 Review.
-
Metal fumes in foundries.Scand J Work Environ Health. 1976;2 Suppl 1:42-9. doi: 10.5271/sjweh.2833. Scand J Work Environ Health. 1976. PMID: 968464
-
Characterization of particle exposure in ferrochromium and stainless steel production.J Occup Environ Hyg. 2016 Jul;13(7):558-68. doi: 10.1080/15459624.2016.1159687. J Occup Environ Hyg. 2016. PMID: 26950803
-
Magnetite and magnetotaxis in microorganisms.Bioelectromagnetics. 1989;10(3):223-37. doi: 10.1002/bem.2250100303. Bioelectromagnetics. 1989. PMID: 2665749 Review.