Physical properties of aerosols produced by several jet- and ultrasonic nebulizers
- PMID: 6704568
Physical properties of aerosols produced by several jet- and ultrasonic nebulizers
Abstract
In order to estimate the administered dose of inhaled drugs from aqueous aerosols, we have examined the output characteristics of eleven jet- and nine ultrasonic nebulizers. Under various operating conditions we measured driving pressure, airflow, solution- and solute output of the nebulizers, particle concentration and size distribution in the aerosol. The particle size distributions were determined of the dry particles from evaporated droplets of aerosolized 9 mg X ml-1 NaCl solutions by using a mobility aerosols spectrometer. These physical properties of the aerosols were found to vary considerably between nebulizers (even among specimens of the same type). Solution output per litre of air from the ultrasonic devices was 2 to 10 times larger than that from the jets, being dependent on electric power and driving pressure respectively. The jet nebulizers showed the largest particle concentration per litre of air. The volume median aerodynamic diameter of the droplets generated by the jet nebulizers was about 1.5-4 microns. With the exception of the Siemens TV 6000 and the Bosch Halomed, this diameter ranged between 3 and 7 microns among the ultrasonic nebulizers, being dependent on the frequency of the ultrasonic vibrations. The output characteristics appeared also to be affected by extension tubes, air vents, solute concentration and airflow. Solute output varied nonproportionally with solution output, which confirms the comparative merit of output measurements by weighing. The results of the present study can be used to estimate the administered dose of therapeutic or provocative agents by nebulizer equipment. Actual drug output can only be quantified by careful calibration of each separate set-up.
Similar articles
-
The physical properties of a jet-nebulizer and their relevance for the histamine provocation test.Bull Eur Physiopathol Respir. 1983 Jan-Feb;19(1):27-36. Bull Eur Physiopathol Respir. 1983. PMID: 6850144
-
Formulations generated from ethanol-based proliposomes for delivery via medical nebulizers.J Pharm Pharmacol. 2006 Jul;58(7):887-94. doi: 10.1211/jpp.58.7.0002. J Pharm Pharmacol. 2006. PMID: 16805947
-
Comparison of a respiratory suspension aerosolized by an air-jet and an ultrasonic nebulizer.Pharm Dev Technol. 1996 Oct;1(3):261-8. doi: 10.3109/10837459609022594. Pharm Dev Technol. 1996. PMID: 9552308
-
Design principles of liquid nebulization devices currently in use.Respir Care. 2002 Nov;47(11):1257-75; discussion 1275-8. Respir Care. 2002. PMID: 12425742 Review.
-
Formulations and nebulizer performance.Respir Care. 2002 Nov;47(11):1305-12; discussion 1312-3. Respir Care. 2002. PMID: 12425745 Review.
Cited by
-
Effects of Temperature and Humidity on Laser Diffraction Measurements to Jet Nebulizer and Comparison with NGI.AAPS PharmSciTech. 2016 Apr;17(2):380-8. doi: 10.1208/s12249-015-0346-5. Epub 2015 Jul 14. AAPS PharmSciTech. 2016. PMID: 26169901 Free PMC article.
-
Inhaled chemotherapy adverse effects: mechanisms and protection methods.Lung Cancer Manag. 2020 Jan 16;8(4):LMT19. doi: 10.2217/lmt-2019-0007. Lung Cancer Manag. 2020. PMID: 31983927 Free PMC article. Review.
-
Nebuliser performance, pharmacokinetics, airways and systemic effects of salbutamol given via a novel nebuliser delivery system ("Ventstream").Thorax. 1994 Aug;49(8):762-70. doi: 10.1136/thx.49.8.762. Thorax. 1994. PMID: 8091320 Free PMC article. Clinical Trial.
-
Effect of low dose nebulised morphine on exercise endurance in patients with chronic lung disease.Thorax. 1989 May;44(5):387-90. doi: 10.1136/thx.44.5.387. Thorax. 1989. PMID: 2669222 Free PMC article. Clinical Trial.
-
Nebulisers: uses and abuses.Arch Dis Child. 1986 May;61(5):424-5. doi: 10.1136/adc.61.5.424. Arch Dis Child. 1986. PMID: 3717987 Free PMC article. No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources