Interrupter technique for measurement of respiratory mechanics in anesthetized cats
- PMID: 6706775
- DOI: 10.1152/jappl.1984.56.3.681
Interrupter technique for measurement of respiratory mechanics in anesthetized cats
Abstract
In six spontaneously breathing anesthetized cats (pentobarbital sodium, 35 mg/kg ip), airflow, changes in lung volume, and tracheal and esophageal pressures were measured. Airflow was interrupted by brief airway occlusions during relaxed expirations (elicited via the Breuer-Hering inflation reflex) and throughout spontaneous breaths. A plateau in tracheal pressure occurred throughout relaxed expirations and the latter part of spontaneous expirations indicating respiratory muscle relaxation. Measurement of tracheal pressure, immediately preceding airflow, and corresponding volume enabled determination of respiratory system elastance and flow resistance. These were partitioned into lung and chest wall components using esophageal pressure. Respiratory system elastance was constant over the tidal volume range, divided approximately equally between the lung and chest wall. While the passive pressure-flow relationship for the respiratory system was linear, those for the lung and chest wall were curvilinear. Volume dependence of chest wall flow resistance was demonstrated. During inspiratory interruptions, tracheal pressure increased progressively; initial tracheal pressure was estimated by backward extrapolation. Inspiratory flow resistance of the lung and total respiratory system were constant. Force-velocity properties of the contracting inspiratory muscles contributed little to overall active resistance.
Similar articles
-
Single-breath method for measurement of respiratory mechanics in anesthetized animals.J Appl Physiol Respir Environ Exerc Physiol. 1982 May;52(5):1266-71. doi: 10.1152/jappl.1982.52.5.1266. J Appl Physiol Respir Environ Exerc Physiol. 1982. PMID: 7096151
-
Respiratory system, lung, and chest wall mechanics in guinea pigs.Braz J Med Biol Res. 1988;21(2):353-63. Braz J Med Biol Res. 1988. PMID: 3060208 Review.
-
Decay of inspiratory muscle pressure during expiration in anesthetized cats.J Appl Physiol Respir Environ Exerc Physiol. 1983 Feb;54(2):408-13. doi: 10.1152/jappl.1983.54.2.408. J Appl Physiol Respir Environ Exerc Physiol. 1983. PMID: 6833038
-
Active and passive respiratory mechanics in anesthetized dogs.J Appl Physiol (1985). 1986 Nov;61(5):1647-55. doi: 10.1152/jappl.1986.61.5.1647. J Appl Physiol (1985). 1986. PMID: 3781977
-
Respiratory mechanics in kyphoscoliosis.Monaldi Arch Chest Dis. 1993;48(1):69-79. Monaldi Arch Chest Dis. 1993. PMID: 8472069 Review.
Cited by
-
Disturbance in respiratory mechanics in infants with bronchiolitis.Thorax. 1989 Aug;44(8):660-7. doi: 10.1136/thx.44.8.660. Thorax. 1989. PMID: 2799745 Free PMC article.
-
Estimation of expiratory time constants via fuzzy clustering.J Clin Monit Comput. 2002 Jan;17(1):15-22. doi: 10.1023/a:1015484607616. J Clin Monit Comput. 2002. PMID: 12102244
-
Intrinsic positive end-expiratory pressure (PEEPi).Intensive Care Med. 1995 Jun;21(6):522-36. doi: 10.1007/BF01706208. Intensive Care Med. 1995. PMID: 7560497 Review. No abstract available.
-
Assessment of induced bronchoconstriction in anesthetized cats by the end-inflation occlusion method.Lung. 1989;167(3):149-61. doi: 10.1007/BF02714944. Lung. 1989. PMID: 2500568
-
Effects of the components of positive airway pressure on work of breathing during bronchospasm.Crit Care. 2004 Apr;8(2):R72-81. doi: 10.1186/cc2461. Epub 2004 Feb 9. Crit Care. 2004. PMID: 15025781 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources