Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1978 Jun:279:621-40.
doi: 10.1113/jphysiol.1978.sp012365.

Albumin permeability of the peritubular capillaries in rat renal cortex

Albumin permeability of the peritubular capillaries in rat renal cortex

D R Bell et al. J Physiol. 1978 Jun.

Abstract

1. Two series of experiments were carried out to determine the permeability of the renal cortical peritubular capillaries to albumin under control conditions in the concentrating kidney and after an infusion of hypo-osmotic fluid amounting to 6% body weight. 2. In the first series of these experiments the turnover of the interstitial albumin pool of the renal cortex was studied. Specifically, the mean transit time of albumin molecules from arterial plasma to renal lymph was measured in nine rats of each group. Mean values of 39.0 +/- 2.8 and 30.6 +/- 2.2 (S.E. of mean) min were found for the control and infused groups, respectively. 3. In the second series of experiments the interstitial distribution volume of plasma albumin in renal cortex was determined in twenty-three control and twenty-two infused rats. Mean values of the extravascular distribution volumes were 1.66 +/- 0.21 and 1.37 +/- 0.18 (S.E. of mean) microliter/100 mg tissue, respectively. 4. The unidirectional clearance of albumin from the capillary to the interstitium in the control and infused groups, respectively, was calculated to be 7.1 +/- 1.0 and 7.5 +/- 0.9 (S.E. of mean) ml. sec-1 10(-4) in 100 g cortical tissue. 5. For the reabsorbing surface of the peritubular capillaries in the renal cortex, a lower bound was calculated for sigma, the reflexion coefficient of albumin. The reflexion coefficient was found to be higher than 0.998 under both experimental conditions.

PubMed Disclaimer

References

    1. J Physiol. 1896 May 5;19(4):312-26 - PubMed
    1. J Appl Physiol. 1954 Jun;6(12):731-44 - PubMed
    1. Am J Physiol. 1977 Oct;233(4):F269-73 - PubMed
    1. Int J Nucl Med Biol. 1977 Jan;4(1):43-6 - PubMed
    1. Int Rev Physiol. 1976;11:145-67 - PubMed

Publication types

LinkOut - more resources