Photometric oculometry. I. An analysis of the optical principles in slit-lamp fluorophotometry
- PMID: 6720293
- DOI: 10.1111/j.1755-3768.1984.tb08404.x
Photometric oculometry. I. An analysis of the optical principles in slit-lamp fluorophotometry
Abstract
The optical principles of slit-lamp fluorophotometry are analysed by aid of a mathematical model of the optical system. The analysis forms the theoretical basis for a slit-lamp technique called photometric oculometry, which makes possible an estimation of intraocular axial distances and axial length. The technique is based on a calculation--by aid of a mathematical model of the eye--of the ratio between intraocular movement of the slit-lamp focal plane and corresponding movement of the slit-lamp. Intraocular axial distances can be calculated by aid of this ratio and a direct measurement of the slit-lamp movement when the focal plane is moved in the optical axis from retina to cornea. These items are prerequisites for a quantitative determination of the blood-retinal barrier permeability to fluorescein during vitreous fluorophotometry.
Similar articles
-
Photometric oculometry: a slit-lamp technique for determination of intraocular distances.Graefes Arch Clin Exp Ophthalmol. 1985;222(4-5):212-4. doi: 10.1007/BF02133677. Graefes Arch Clin Exp Ophthalmol. 1985. PMID: 3884455
-
Photometric oculometry. II. Measurement of axial ocular distances with slit-lamp microscopy. Clinical evaluation, and comparison with ultrasonography.Acta Ophthalmol (Copenh). 1984 Apr;62(2):290-9. Acta Ophthalmol (Copenh). 1984. PMID: 6720294
-
Quantitative vitreous fluorophotometry applying a mathematical model of the eye.Invest Ophthalmol Vis Sci. 1985 May;26(5):698-710. Invest Ophthalmol Vis Sci. 1985. PMID: 3997419
-
Ocular fluorometry methodological improvements and clinical studies--with special reference to the blood-retina barrier permeability to fluorescein and fluorescein glucuronide.Acta Ophthalmol Suppl (1985). 1993;(211):1-52. Acta Ophthalmol Suppl (1985). 1993. PMID: 8318868 Review.
-
Fluorophotometric evaluation of the blood-ocular barrier function following cataract surgery and intraocular lens implantation.J Cataract Refract Surg. 1988 Sep;14(5):560-8. doi: 10.1016/s0886-3350(88)80016-6. J Cataract Refract Surg. 1988. PMID: 3054055 Review.
Cited by
-
Depth measurement with the slit-lamp microscope.Br J Ophthalmol. 1988 May;72(5):344-7. doi: 10.1136/bjo.72.5.344. Br J Ophthalmol. 1988. PMID: 3395593 Free PMC article.
-
Fluorescein and fluorescein glucuronide in the vitreous body of diabetic patients.Graefes Arch Clin Exp Ophthalmol. 1987;225(3):173-6. doi: 10.1007/BF02175445. Graefes Arch Clin Exp Ophthalmol. 1987. PMID: 3609757
-
Calculation of the permeability of the blood-retinal barrier to fluorescein.Graefes Arch Clin Exp Ophthalmol. 1985;222(4-5):173-6. doi: 10.1007/BF02133667. Graefes Arch Clin Exp Ophthalmol. 1985. PMID: 3979839
-
Photometric oculometry: a slit-lamp technique for determination of intraocular distances.Graefes Arch Clin Exp Ophthalmol. 1985;222(4-5):212-4. doi: 10.1007/BF02133677. Graefes Arch Clin Exp Ophthalmol. 1985. PMID: 3884455
-
Determination of spatial coordinates in ocular fluorometry.Graefes Arch Clin Exp Ophthalmol. 1991;229(4):358-62. doi: 10.1007/BF00170695. Graefes Arch Clin Exp Ophthalmol. 1991. PMID: 1916324