Photometric oculometry. II. Measurement of axial ocular distances with slit-lamp microscopy. Clinical evaluation, and comparison with ultrasonography
- PMID: 6720294
Photometric oculometry. II. Measurement of axial ocular distances with slit-lamp microscopy. Clinical evaluation, and comparison with ultrasonography
Abstract
Photometric oculometry is a slit-lamp technique, which makes possible an estimation of intraocular axial distances and axial length. The technique is based on a transformation of a sagittal slit-lamp movement into intraocular axial distances when the slit-lamp focal plane is moved in the optical axis from retina to cornea. Determination of the axial length in 50 eyes (refractive range +4.75 to -5.25 D) showed that the axial length varied from 21.9 mm in hypermetropic eyes to 26.0 mm in myopic eyes, with the emmetropic eyes being approximately 24 mm. A comparison of intraocular axial distances determined by photometric oculometry and by ultrasonography on a small series of eyes showed no significant differences between the axial length, the length of the vitreous body, and the lens thickness, whereas a significant difference between the anterior chamber depth was observed (photometry giving slightly larger values than ultrasound).
Similar articles
-
Photometric oculometry: a slit-lamp technique for determination of intraocular distances.Graefes Arch Clin Exp Ophthalmol. 1985;222(4-5):212-4. doi: 10.1007/BF02133677. Graefes Arch Clin Exp Ophthalmol. 1985. PMID: 3884455
-
Photometric oculometry. I. An analysis of the optical principles in slit-lamp fluorophotometry.Acta Ophthalmol (Copenh). 1984 Apr;62(2):274-89. doi: 10.1111/j.1755-3768.1984.tb08404.x. Acta Ophthalmol (Copenh). 1984. PMID: 6720293
-
A biometric investigation of ocular components in amblyopia.Ophthalmic Physiol Opt. 2008 Sep;28(5):429-40. doi: 10.1111/j.1475-1313.2008.00585.x. Ophthalmic Physiol Opt. 2008. PMID: 18761480
-
The role of the lens in refractive development of the eye: animal models of ametropia.Exp Eye Res. 2008 Jul;87(1):3-8. doi: 10.1016/j.exer.2008.03.001. Epub 2008 Mar 18. Exp Eye Res. 2008. PMID: 18405895 Review.
-
Slit Lamp-Based Ocular Scoring Systems in Toxicology and Drug Development: A Literature Survey.J Ocul Pharmacol Ther. 2017 Dec;33(10):707-717. doi: 10.1089/jop.2017.0021. Epub 2017 Nov 7. J Ocul Pharmacol Ther. 2017. PMID: 29111862 Review.
Cited by
-
Axial biometry of the entire eye using ultra-long scan depth optical coherence tomography.Am J Ophthalmol. 2014 Feb;157(2):412-420.e2. doi: 10.1016/j.ajo.2013.09.033. Epub 2013 Oct 7. Am J Ophthalmol. 2014. PMID: 24332374 Free PMC article.
-
Photometric oculometry: a slit-lamp technique for determination of intraocular distances.Graefes Arch Clin Exp Ophthalmol. 1985;222(4-5):212-4. doi: 10.1007/BF02133677. Graefes Arch Clin Exp Ophthalmol. 1985. PMID: 3884455
-
Fluorescein and fluorescein glucuronide in the vitreous body of diabetic patients.Graefes Arch Clin Exp Ophthalmol. 1987;225(3):173-6. doi: 10.1007/BF02175445. Graefes Arch Clin Exp Ophthalmol. 1987. PMID: 3609757
-
Determination of spatial coordinates in ocular fluorometry.Graefes Arch Clin Exp Ophthalmol. 1991;229(4):358-62. doi: 10.1007/BF00170695. Graefes Arch Clin Exp Ophthalmol. 1991. PMID: 1916324