Morphometry of human leukocytes
- PMID: 6775712
Morphometry of human leukocytes
Abstract
In order to establish quantitative models of leukocyte functions, several morphometric parameters on individual white cells are needed. These include the diameter, volume, and membrane area of the cells and their nuclei in the undeformed state. A stereologic method was used to obtain these quantities from transmission electron microscopy of random sections through human white blood cells (neutrophils, lymphocytes, monocytes, and eosinophils). In order to estimate possible artifacts due to preparation of the cells for transmission electron microscopy, a detailed comparison with light microscopy was made. The results show that undeformed white cells in isotonic solution are spherical with many membrane foldings and have a significantly smaller diameter than that measured on blood smears. A method of chemical fixation was employed so that the shrinkage due to fixation of the cells is below the resolution of light microscopic measurements. Further, it was shown that all leukocytes, including lymphocytes, have much more membrane area than is needed to cover their volumes, and this membrane area remains constant when the cell is hypotonically swollen.
Similar articles
-
Deformation of leukocytes on a hematological blood film.Biorheology. 1984;21(6):767-81. doi: 10.3233/bir-1984-21604. Biorheology. 1984. PMID: 6518289
-
The flow of blood cell suspensions through 3 microns and 5 microns Nuclepore membranes: a comparison of kinetic analysis with scanning electron microscopic examinations.Br J Haematol. 1985 Mar;59(3):541-6. doi: 10.1111/j.1365-2141.1985.tb07341.x. Br J Haematol. 1985. PMID: 3970865
-
Scanning electron microscopy of normal human peripheral blood cells.Taiwan Yi Xue Hui Za Zhi. 1989 Nov-Dec;88(11-12):1128-32. Taiwan Yi Xue Hui Za Zhi. 1989. PMID: 2636250
-
Leukocyte biophysics. An invited review.Cell Biophys. 1990 Oct;17(2):107-35. doi: 10.1007/BF02990492. Cell Biophys. 1990. PMID: 1705479 Review.
-
Morphometry of human blood leukocyte ultrastructure: its potential value in haematology.Haematologia (Budap). 1988;21(3):129-39. Haematologia (Budap). 1988. PMID: 3053357 Review.
Cited by
-
Numerical simulation of a single cell passing through a narrow slit.Biomech Model Mechanobiol. 2016 Dec;15(6):1655-1667. doi: 10.1007/s10237-016-0789-y. Epub 2016 Apr 15. Biomech Model Mechanobiol. 2016. PMID: 27080221 Free PMC article.
-
Noninvasive in vivo characterization of erythrocyte motion in human retinal capillaries using high-speed adaptive optics near-confocal imaging.Biomed Opt Express. 2018 Jul 12;9(8):3653-3677. doi: 10.1364/BOE.9.003653. eCollection 2018 Aug 1. Biomed Opt Express. 2018. PMID: 30338146 Free PMC article.
-
Tyrosine sulfation of native mouse Psgl-1 is required for optimal leukocyte rolling on P-selectin in vivo.PLoS One. 2011;6(5):e20406. doi: 10.1371/journal.pone.0020406. Epub 2011 May 25. PLoS One. 2011. PMID: 21633705 Free PMC article.
-
Deformability based Cell Sorting using Microfluidic Ratchets Enabling Phenotypic Separation of Leukocytes Directly from Whole Blood.Sci Rep. 2017 Jul 26;7(1):6627. doi: 10.1038/s41598-017-06865-x. Sci Rep. 2017. PMID: 28747668 Free PMC article.
-
Characterization of molecular transport in ultrathin hydrogel coatings for cellular immunoprotection.Biomacromolecules. 2015 Feb 9;16(2):541-9. doi: 10.1021/bm501594x. Epub 2015 Jan 27. Biomacromolecules. 2015. PMID: 25592156 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources