Dynamic computed tomography of the brain: techniques, data analysis, and applications
- PMID: 6784472
- DOI: 10.2214/ajr.136.4.759
Dynamic computed tomography of the brain: techniques, data analysis, and applications
Abstract
Rapid sequence computed tomography (CT) scanning has many potential applications in studying intracranial physiologic events. However, visual inspection of these rapid sequence scans fails to extract the large amount of information inherent in the digital data. The concept of corrected mean transit time applied to rapid sequence scans after intravenous bolus injection of contrast material provides quantitative data on relative hemispheric flow. Use of histogram-based areas of interest permits accurate and reproducible identification of anatomic structures including arteries and gray and white matter. Gamma variate curve fit techniques reduce statistical noise. The concept of transit time can be expanded to the creation of functional CT images.
Similar articles
-
Functional imaging of the brain using computed tomography.Radiology. 1981 Mar;138(3):711-6. doi: 10.1148/radiology.138.3.7465851. Radiology. 1981. PMID: 7465851
-
Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis.Radiology. 1980 Dec;137(3):679-86. doi: 10.1148/radiology.137.3.7003648. Radiology. 1980. PMID: 7003648
-
Dynamic cranial computed tomography: preliminary results.AJR Am J Roentgenol. 1980 May;134(5):941-5. doi: 10.2214/ajr.134.5.941. AJR Am J Roentgenol. 1980. PMID: 6768269
-
Intravascular functional maps of common neurovascular lesions derived from volumetric 4D CT data.Invest Radiol. 2010 Jul;45(7):370-7. doi: 10.1097/RLI.0b013e3181e1939d. Invest Radiol. 2010. PMID: 20479649
-
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.Semin Nucl Med. 2003 Jul;33(3):166-79. doi: 10.1053/snuc.2003.127307. Semin Nucl Med. 2003. PMID: 12931319 Review.
Cited by
-
Dynamic computed tomography of the brain.Neurosurg Rev. 1985;8(1):15-25. doi: 10.1007/BF01744874. Neurosurg Rev. 1985. PMID: 4022396
-
Cerebral perfusion computerized tomography: influence of reference vessels, regions of interest and interobserver variability.Neuroradiology. 2006 Sep;48(9):670-7. doi: 10.1007/s00234-006-0099-7. Epub 2006 May 23. Neuroradiology. 2006. PMID: 16718460
-
Dynamic CT perfusion to assess the effect of carotid revascularization in chronic cerebral ischemia.AJNR Am J Neuroradiol. 2000 Feb;21(2):421-5. AJNR Am J Neuroradiol. 2000. PMID: 10696034 Free PMC article.
-
Evaluation of hepatic density change by dynamic CT in healthy humans and in patients with chronic liver diseases.Dig Dis Sci. 1992 Feb;37(2):220-4. doi: 10.1007/BF01308175. Dig Dis Sci. 1992. PMID: 1735339
-
The value of diagnostic imaging techniques in the management of diseases of the nervous system.Can Med Assoc J. 1984 Jun 1;130(11):1425-6. Can Med Assoc J. 1984. PMID: 6610468 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical