The dosimetry of fixed, single source hemibody and total body irradiators
- PMID: 6810077
- DOI: 10.1118/1.595091
The dosimetry of fixed, single source hemibody and total body irradiators
Abstract
Increasingly, hemibody and total body irradiation are used to treat systemic and disseminated diseases. Certain dosimetry considerations are common to conventional treatments at short source-to-axis distances and large field treatments at extended treatment distances. These dosimetry considerations include: irradiation geometry, dose rates or outputs in the treatment plane, radiation intensity uniformity, confirmation of the dose ratio parameters such as percentage depth doses, tissue air ratios, tissue maximum ratios, and tissue phantom ratios, the surface doses and the doses in the region of build-up to maximum ionization, the exit doses, the dose prescription point or points, dose uniformity in the patient, and dose confirmation and verification. Some radiotherapists are reluctant to treat patients using large fields at extended treatment distances because they are unfamiliar with the dosimetry of such treatments. This article reviews the dosimetry and radiobiology of large field treatments at the extended treatment distances required by hemibody or total body irradiation, as performed with conventional single source teletherapy units.
Similar articles
-
Matching the dosimetry characteristics of a dual-field Stanford technique to a customized single-field Stanford technique for total skin electron therapy.Int J Radiat Oncol Biol Phys. 2004 Jul 1;59(3):872-85. doi: 10.1016/j.ijrobp.2004.02.046. Int J Radiat Oncol Biol Phys. 2004. PMID: 15183491
-
Modification of a standard cobalt-60 unit for total body irradiation at 150 cm SSD.Int J Radiat Oncol Biol Phys. 1984 Jun;10(6):927-32. doi: 10.1016/0360-3016(84)90397-3. Int J Radiat Oncol Biol Phys. 1984. PMID: 6376434
-
Total body irradiation with translation method.Radiother Oncol. 1996 Mar;38(3):253-5. doi: 10.1016/0167-8140(95)01697-x. Radiother Oncol. 1996. PMID: 8693107
-
In vivo dosimetry for tangential breast irradiation: role of the equipment in the accuracy of dose delivery.Radiother Oncol. 1991 Dec;22(4):285-9. doi: 10.1016/0167-8140(91)90164-c. Radiother Oncol. 1991. PMID: 1792322 Review.
-
Techniques applied for total body irradiation.Radiother Oncol. 1990;18 Suppl 1:10-5. doi: 10.1016/0167-8140(90)90174-u. Radiother Oncol. 1990. PMID: 2247629 Review.
Cited by
-
Whole body radiotherapy: A TBI-guideline.J Med Phys. 2006 Jan;31(1):5-12. doi: 10.4103/0971-6203.25664. J Med Phys. 2006. PMID: 21206634 Free PMC article.
-
Protective effects of selenocystine against γ-radiation-induced genotoxicity in Swiss albino mice.Radiat Environ Biophys. 2011 May;50(2):271-80. doi: 10.1007/s00411-011-0352-2. Epub 2011 Jan 23. Radiat Environ Biophys. 2011. PMID: 21259021
-
A translational couch technique for total body irradiation.J Appl Clin Med Phys. 2001 Autumn;2(4):201-9. doi: 10.1120/jacmp.v2i4.2597. J Appl Clin Med Phys. 2001. PMID: 11686741 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources