Application of the CYTOMIC 12 flow cytometric compact analyzer for automatic kinetic measurements
- PMID: 6822145
- DOI: 10.1002/cyto.990030403
Application of the CYTOMIC 12 flow cytometric compact analyzer for automatic kinetic measurements
Abstract
Flow cytometry, usually applied to cells which have time independent features, can also be used for kinetic experiments where the change of cell populations with time is investigated. Dedicated time sequencing programs written in Assembler and incorporated in the CYTOMIC 12 analyzer (4) are described. A sequence of 64 one parameter histograms can be automatically acquired and immediately displayed as a pseudo-two-parameter histogram. The acquisition time for each of the subsequent histograms can be selected between 1 and 32 seconds. Kinetics lasting up to 34 minutes are resolved into 64 time intervals. Two parameter kinetics can be resolved into 12 32 X 32 channel, two parameter histograms which are displayed and evaluated immediately on the analyzer screen in groups of 4 without using complicated list mode procedures. The standard CYTOMIC 12 software can be applied for processing and printing of the sequence distribution curves.
Similar articles
-
"Cytomic" data system modules--modern electronic devices for flow cytometric data handling and presentation.Cytometry. 1984 May;5(3):299-303. doi: 10.1002/cyto.990050313. Cytometry. 1984. PMID: 6734354
-
On-line three-parameter data uptake, analysis, and display device for flow cytometry and other applications.Cytometry. 1986 Jan;7(1):25-40. doi: 10.1002/cyto.990070105. Cytometry. 1986. PMID: 3753919
-
Eight-parameter PC-AT based flow cytometric data system.Cytometry. 1990;11(7):805-12. doi: 10.1002/cyto.990110706. Cytometry. 1990. PMID: 2272245 Review.
-
Realtime acquisition, storage, and display of correlated three-parameter flow cytometric data.Cytometry. 1986 Jan;7(1):82-8. doi: 10.1002/cyto.990070112. Cytometry. 1986. PMID: 3753920
-
Automatic analysis of flow cytometric DNA histograms from irradiated mouse male germ cells.Cytometry. 1989 Jan;10(1):62-9. doi: 10.1002/cyto.990100111. Cytometry. 1989. PMID: 2645097 Review.
Cited by
-
Measurement of efflux from G1-phase in a growth factor dependent cell line.Acta Biotheor. 1992 Sep;40(2-3):139-46. doi: 10.1007/BF00168143. Acta Biotheor. 1992. PMID: 1462732
-
A new method for fast blood cell counting and partial differentiation by flow cytometry.Blut. 1984 Aug;49(2):83-90. doi: 10.1007/BF00363698. Blut. 1984. PMID: 6205708
MeSH terms
LinkOut - more resources
Full Text Sources