Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1983 Feb;17(2):249-54.
doi: 10.1128/jcm.17.2.249-254.1983.

Comparison of a new rapid plasma reagin card test with the standard rapid plasma reagin 18-mm circle card test and the venereal disease research laboratory slide test for serodiagnosis of syphilis

Comparative Study

Comparison of a new rapid plasma reagin card test with the standard rapid plasma reagin 18-mm circle card test and the venereal disease research laboratory slide test for serodiagnosis of syphilis

E A Hambie et al. J Clin Microbiol. 1983 Feb.

Abstract

The rapid plasma reagin (RPR) card test manufactured by Beckman Instruments, Inc., was compared, qualitatively and quantitatively, with the Venereal Disease Research Laboratory (VDRL) slide test and the standard RPR 18-mm circle card tests for the serodiagnosis of syphilis. Sera from 638 individuals were used in this study. Two pilot lots and two production lots of antigen were submitted by Beckman Instruments, Inc., for evaluation. Qualitative agreement among the three RPR card tests was 98.1%; between the Beckman RPR card and the VDRL slide tests, 95.0%; and between the reference RPR card and the VDRL slide tests, 95.5%. The Beckman RPR card test was 95.3% specific, whereas the specificities of the reference RPR card and the VDRL slide tests were 98.8% and 96.1%, respectively. Sensitivities of the three nontreponemal tests were: Beckman RPR card test production lots, 94.7%; reference RPR card test, 96.8%; and VDRL slide test, 90.6%. Quantitative agreement +/- 1 dilution among the three RPR card tests was 93.0%, whereas quantitative agreement was approximately 40% when both RPR card tests were compared with the VDRL slide test. We found the Beckman RPR card test comparable to the standard RPR card tests. Therefore, the decision of which test to use for the serodiagnosis of syphilis is at the discretion of the user.

PubMed Disclaimer

References

    1. Sex Transm Dis. 1980 Apr-Jun;7(2):66-70 - PubMed
    1. J Clin Microbiol. 1982 Aug;16(2):286-90 - PubMed
    1. Am J Clin Pathol. 1963 Nov;40:473-9 - PubMed

Publication types

LinkOut - more resources