Comparison of four rapid methods for identification of Enterobacteriaceae from blood cultures
- PMID: 6841583
- PMCID: PMC272673
- DOI: 10.1128/jcm.17.3.493-499.1983
Comparison of four rapid methods for identification of Enterobacteriaceae from blood cultures
Abstract
Positive blood cultures containing gram-negative bacilli were utilized for direct identification by two automated systems, the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.) and the MS-2 (Abbott Diagnostics, Dallas, Tex.), and two commercial kits, the Micro-ID system (General Diagnostics, Warner-Lambert Co., Morris Plains, N.J.) and the same-day API 20E (Analytab Products, Plainview, N.Y.). Samples of 10 to 15 ml were aseptically removed from radiometrically positive BACTEC bottles (Johnston Laboratories, Cockeysville, Md.) and divided among four sterile tubes. The tubes were centrifuged at 107 X g for 10 min. The supernatants were centrifuged at 1,510 X g for 10 min, and pellets were tested for cytochrome oxidase by means of Pathotec strips. Oxidase-negative pellets were suspended in appropriate media as suggested by the manufacturers. All systems were inoculated, incubated, and interpreted according to the instructions of the manufacturers. The Micro-ID system was read after 4 h of incubation; the three remaining systems were read after 5 h. Results were compared with those of the 18-h API 20E inoculated from pure subcultures of the organisms. Correlation of 90% or more with the API 20E was achieved by the AutoMicrobic and Micro-ID systems. The same-day API 20E and the MS-2 demonstrated 60 and 44% correlation, respectively, with the 18-h API 20E.
Similar articles
-
Clinical evaluation of the MICRO-ID, API 20E, and conventional media systems for identification of Enterobacteriacea.J Clin Microbiol. 1979 Aug;10(2):161-7. doi: 10.1128/jcm.10.2.161-167.1979. J Clin Microbiol. 1979. PMID: 389946 Free PMC article.
-
Laboratory evaluation of the AutoMicrobic system for identification of Enterobacteriaceae.J Clin Microbiol. 1981 May;13(5):895-8. doi: 10.1128/jcm.13.5.895-898.1981. J Clin Microbiol. 1981. PMID: 7016913 Free PMC article.
-
Parallel comparison of accuracy of API 20E, Vitek GNI, MicroScan Walk/Away Rapid ID, and Becton Dickinson Cobas Micro ID-E/NF for identification of members of the family Enterobacteriaceae and common gram-negative, non-glucose-fermenting bacilli.J Clin Microbiol. 1993 Dec;31(12):3165-9. doi: 10.1128/jcm.31.12.3165-3169.1993. J Clin Microbiol. 1993. PMID: 8308108 Free PMC article.
-
Comparison of Crystal Enteric/Nonfermenter system, API 20E system, and Vitek AutoMicrobic system for identification of gram-negative bacilli.J Clin Microbiol. 1995 Feb;33(2):364-70. doi: 10.1128/jcm.33.2.364-370.1995. J Clin Microbiol. 1995. PMID: 7714193 Free PMC article.
-
Time-motion and cost comparison study of micro-ID, API 20E, and conventional biochemical testing in identification of Enterobacteriaceae.J Clin Microbiol. 1981 Dec;14(6):665-70. doi: 10.1128/jcm.14.6.665-670.1981. J Clin Microbiol. 1981. PMID: 6801085 Free PMC article.
Cited by
-
Comparison of an in-house method and the commercial Sepsityper™ kit for bacterial identification directly from positive blood culture broths by matrix-assisted laser desorption-ionisation time-of-flight mass spectrometry.Eur J Clin Microbiol Infect Dis. 2012 Sep;31(9):2269-81. doi: 10.1007/s10096-012-1566-1. Epub 2012 Feb 25. Eur J Clin Microbiol Infect Dis. 2012. PMID: 22367290
-
Four-hour direct identification of Enterobacteriaceae in blood cultures.Eur J Clin Microbiol. 1983 Dec;2(6):593-5. doi: 10.1007/BF02016573. Eur J Clin Microbiol. 1983. PMID: 6365538 No abstract available.
-
Evaluation of the Cobas-Bact system for direct and rapid identification and antimicrobial susceptibility testing of gram-negative rods from positive blood culture broths.J Clin Microbiol. 1989 Jan;27(1):102-5. doi: 10.1128/jcm.27.1.102-105.1989. J Clin Microbiol. 1989. PMID: 2643613 Free PMC article.
-
Direct identification and susceptibility testing of gram-negative bacilli from BACTEC bottles by use of the MS-2 system with updated bacterial identification software.J Clin Microbiol. 1984 Dec;20(6):1202-4. doi: 10.1128/jcm.20.6.1202-1204.1984. J Clin Microbiol. 1984. PMID: 6394624 Free PMC article.
-
Rapid presumptive identification of gram-negative rods directly from blood cultures by simple enzymatic tests.J Clin Microbiol. 1990 Feb;28(2):177-81. doi: 10.1128/jcm.28.2.177-181.1990. J Clin Microbiol. 1990. PMID: 2107196 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical