Abstract
Eighty-one patients with diagnostically difficult clinical presentations suggesting coronary disease underwent symptom-limited maximal-exercise treadmill testing (ETT) and exercise radionuclide scanning with thallium-201. Results of these tests were in agreement in only 47 percent of the cases. Either exercise thallium or ETT was positive in 94 percent of patients with disease. Among a population with a disease prevalence of 67 percent, agreement between exercise thallium an ETT predicted disease in 92 percent of instances or excluded disease in 82 percent of instances. Frequent discordance between these two tests in 53 percent of the cases unfortunately limits this usefulness.
Similar articles
-
Reliability of stress thallium-201 scanning in the clinical evaluation of coronary artery disease.Clin Nucl Med. 1979 Jun;4(6):225-8. doi: 10.1097/00003072-197906000-00001. Clin Nucl Med. 1979. PMID: 477151
-
[Diagnosis of coronary artery disease: value and limitations of non-invasive methods. (Ecg, thallium perfusion scintigraphy, radionuclide angiography) (author's transl)].Z Kardiol. 1979 Nov;68(11):748-53. Z Kardiol. 1979. PMID: 543193 German.
-
Thallium 201 exercise scintigraphy for detection of multivessel coronary artery disease after transmural myocardial infarction.J Natl Med Assoc. 1984 Dec;76(12):1193-200. J Natl Med Assoc. 1984. PMID: 6512876 Free PMC article.
-
Exercise electrocardiography and stress thallium-201 imaging in coronary artery disease.Cardiovasc Clin. 1983;13(3):253-77. Cardiovasc Clin. 1983. PMID: 6349804 Review. No abstract available.
-
The value of thallium exercise testing in patients with coronary artery disease.Int J Cardiol. 1981;1(1):7-14. doi: 10.1016/0167-5273(81)90041-3. Int J Cardiol. 1981. PMID: 7037660 Review. No abstract available.
Cited by
-
Comparison of planar imaging and single-photon emission computed tomography for the detection and localization of coronary artery disease.Int J Card Imaging. 1993 Jun;9(2):113-9. doi: 10.1007/BF01151435. Int J Card Imaging. 1993. PMID: 8331303
-
Clinical cardiac PET using generator-produced Rb-82: a review.Cardiovasc Intervent Radiol. 1989 Sep-Oct;12(5):245-51. doi: 10.1007/BF02575408. Cardiovasc Intervent Radiol. 1989. PMID: 2514984 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources