Quantitative buffy coat analysis. A new laboratory tool functioning as a screening complete blood cell count
- PMID: 6848870
- DOI: 10.1001/jama.249.5.617
Quantitative buffy coat analysis. A new laboratory tool functioning as a screening complete blood cell count
Abstract
We have developed a system for the quantitative analysis of the buffy coat in centrifuged whole blood samples. This analysis, performed in a modified microhematocrit tube, provides a hematocrit value, total WBC count, platelet count, and a separation of the leukocyte population into granulocytes and nongranulocytes. All results are available within 15 minutes and correlate well with existing methods. The system is expected to provide a rapid means of performing a complete blood cell count in a physician's office.
Similar articles
-
Quantitative buffy coat analysis in haematological patients compared to standard laboratory methods.Scand J Clin Lab Invest. 1990 Oct;50(6):657-61. doi: 10.3109/00365519009089184. Scand J Clin Lab Invest. 1990. PMID: 2247771
-
Quantitative buffy coat analysis of blood collected from dogs, cats, and horses.J Am Vet Med Assoc. 1986 Sep 15;189(6):670-3. J Am Vet Med Assoc. 1986. PMID: 3759633
-
Quantitative buffy coat analysis for hematologic measurements of canine, feline, and equine blood samples and for detection of microfilaremia in dogs.Am J Vet Res. 1988 Mar;49(3):321-4. Am J Vet Res. 1988. PMID: 3358543
-
Clinical implications of automation in cell counting systems.Clin Lab Haematol. 1979;1(1):1-12. doi: 10.1111/j.1365-2257.1979.tb00585.x. Clin Lab Haematol. 1979. PMID: 394902 Review. No abstract available.
-
[Further evolution and leukocyte differential using an automated blood cell counter].Rinsho Byori. 1995 Sep;43(9):925-30. Rinsho Byori. 1995. PMID: 7474456 Review. Japanese.
Cited by
-
The RareCyte® platform for next-generation analysis of circulating tumor cells.Cytometry A. 2018 Dec;93(12):1220-1225. doi: 10.1002/cyto.a.23619. Epub 2018 Oct 2. Cytometry A. 2018. PMID: 30277660 Free PMC article.
-
A rapid dipstick antigen capture assay for the diagnosis of falciparum malaria. WHO Informal Consultation on Recent Advances in Diagnostic Techniques and Vaccines for Malaria.Bull World Health Organ. 1996;74(1):47-54. Bull World Health Organ. 1996. PMID: 8653815 Free PMC article.
-
In vitro antileishmanial properties of tri- and pentavalent antimonial preparations.Antimicrob Agents Chemother. 1995 Jun;39(6):1234-9. doi: 10.1128/AAC.39.6.1234. Antimicrob Agents Chemother. 1995. PMID: 7574507 Free PMC article.
-
Case report: Molecular evidence of Anaplasma platys infection in two women from Venezuela.Am J Trop Med Hyg. 2014 Dec;91(6):1161-5. doi: 10.4269/ajtmh.14-0372. Epub 2014 Sep 29. Am J Trop Med Hyg. 2014. PMID: 25266347 Free PMC article.
-
A Rapid, Quantitative Method to Characterize The Human Lymphocyte Concentration for Automated High-Throughput Radiation Biodosimetry.Biomed Eng Res. 2013 Mar;2(1):16-19. doi: 10.5963/ber0201002. Biomed Eng Res. 2013. PMID: 23781493 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical