Development and validation of a radioimmunoassay for prostaglandin E2 metabolite levels in plasma
- PMID: 6853670
- DOI: 10.1210/jcem-57-1-101
Development and validation of a radioimmunoassay for prostaglandin E2 metabolite levels in plasma
Abstract
Measurements of primary prostaglandins (PGs) in plasma are unreliable, and determinations of their metabolite levels are to be preferred. The principal circulating metabolite of PGE2 [13,14-dihydro-15-keto-PGE2 (PGEM)] is itself unstable however, and this has hindered development of PGE2 metabolite assays. Alkalinization of plasma uniformly converts PGEM and its degradation products to a stable bicyclo compound 11-deoxy-13,14-dihydro-15-keto-11 beta, 16 epsilon-cyclo PGE2 (bicyclo-PGEM). Measurement of bicyclo-PGEM, therefore, enables the PGEM instability problem to be circumvented. This paper describes a specific and sensitive RIA for bicyclo-PGEM in plasma. The assay uses a rabbit antiserum against bicyclo-PGEM and a radiolabel produced by alkalinization of tritiated PGEM. The assay is direct, employing neither chromatographic nor extraction steps. The least detectable mass of bicyclo-PGEM is 1 pg, and the mean mass of added bicyclo-PGEM required to displace zero point binding by 50% is 15 pg. Cross-reactivities of the antiserum against prostanoids are less than 1%. The assay is both accurate and reproducible. Intra- and interassay coefficients of variation are 9.8% and 15.3%, respectively. Plasma concentrations of bicyclo-PGEM in man, rhesus monkey, sheep, and rabbit are reported. This assay allows for reliable measurements of plasma PGE2 metabolites and opens the way for in vivo studies on the significance of PGE2 in health and disease.
Similar articles
-
Maternal plasma prostaglandin E2 metabolite levels during human pregnancy and parturition.Br J Obstet Gynaecol. 1985 Apr;92(4):345-9. doi: 10.1111/j.1471-0528.1985.tb01107.x. Br J Obstet Gynaecol. 1985. PMID: 3857076
-
A sensitive radioimmunoassay for 11-deoxy-13, 14-dihydro-15-keto-11, 16-cyclo-prostaglandin E2: application as an index of prostaglandin E2 biosynthesis during human pregnancy and parturition.Prostaglandins Leukot Med. 1982 Nov;9(5):549-57. doi: 10.1016/0262-1746(82)90036-1. Prostaglandins Leukot Med. 1982. PMID: 6960378
-
A radioimmunoassay for the unstable pulmonary metabolites of prostaglandin E1 and E2: an indirect index of their in vivo disposition and pharmacokinetics.J Pharmacol Exp Ther. 1982 Feb;220(2):229-35. J Pharmacol Exp Ther. 1982. PMID: 6948952
-
Concentration of 13,14-dihydro-15-keto-prostaglandin E2 in the maternal peripheral plasma during labour of spontaneous onset.Br J Obstet Gynaecol. 1984 Mar;91(3):228-31. doi: 10.1111/j.1471-0528.1984.tb04757.x. Br J Obstet Gynaecol. 1984. PMID: 6704346
-
A sensitive radioimmunoassay for 6-keto-prostaglandin F1alpha: preliminary observations on circulating concentrations.Prostaglandins Med. 1978 Jul;1(1):13-21. doi: 10.1016/0161-4630(78)90072-1. Prostaglandins Med. 1978. PMID: 102000
Cited by
-
Topical prostaglandin E2 gel for cervical ripening and closure of the ductus arteriosus in the newborn.Arch Dis Child. 1990 Jul;65(7 Spec No):703-4. doi: 10.1136/adc.65.7_spec_no.703. Arch Dis Child. 1990. PMID: 2386403 Free PMC article.
-
Phase II prospective randomized trial of a low-fat diet with fish oil supplementation in men undergoing radical prostatectomy.Cancer Prev Res (Phila). 2011 Dec;4(12):2062-71. doi: 10.1158/1940-6207.CAPR-11-0298. Epub 2011 Oct 25. Cancer Prev Res (Phila). 2011. PMID: 22027686 Free PMC article. Clinical Trial.
-
Quantitative determination of esterified eicosanoids and related oxygenated metabolites after base hydrolysis.J Lipid Res. 2018 Dec;59(12):2436-2445. doi: 10.1194/jlr.D089516. Epub 2018 Oct 15. J Lipid Res. 2018. PMID: 30323111 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources