[A simple method for the measurement of human gastric emptying: standardization of operative parameters]
- PMID: 6856886
[A simple method for the measurement of human gastric emptying: standardization of operative parameters]
Abstract
The radioisotopic techniques used for the measurement of gastric emptying in man require complex and expensive scintiscanners or gamma-cameras. In this investigation, a simple method utilizing a single and inexpensive detector was evaluated; in addition, the suitability of 99Tcm sulphur colloid as a label for solid meals was assessed. The procedure was found to be accurate and its reproducibility high. The calculated absorbed dose to the gut was very low. Both in vitro and in vivo studies indicate that the radiocolloid used is a food non adsorbable marker for determining gastric emptying of solids. In a group of 50 healthy volunteers the emptying half-time (t1/2) ranged between 40 and 110 min, with a mean of 71.7 +/- 10.1 min, the male subjects exhibiting a significant lower t1/2 than females. In 5 volunteers with t1/2 within the normal range, the effect of drugs acting on gastric motility was evaluated. Hyoscine N-butyl bromide (20 mg) significantly delayed gastric emptying of solids, whereas metoclopramide (20 mg) was ineffective in these subjects. On the contrary, this drug was able to accelerate gastric emptying only in some patients with abnormally delayed emptying. On the whole, the method is simple, inexpensive and reproducible. It may be of great clinical value to investigate abnormalities of gastric function and to perform a better pharmacological approach to the medical treatment.
Similar articles
-
Simultaneous 13C/14C dual isotope breath test measurement of gastric emptying of solid and liquid in normal subjects and patients: comparison with scintigraphy.Nucl Med Rev Cent East Eur. 2003;6(1):29-33. Nucl Med Rev Cent East Eur. 2003. PMID: 14600930 Clinical Trial.
-
Gastric emptying of solid radiopaque markers: studies in healthy subjects and diabetic patients.Gastroenterology. 1984 Oct;87(4):895-902. Gastroenterology. 1984. PMID: 6468877
-
Standardization and quantification of radionuclide solid gastric-emptying studies.J Nucl Med. 2004 May;45(5):760-4. J Nucl Med. 2004. PMID: 15136623
-
Disorders of gastric emptying and the application of radionuclide techniques.Med J Aust. 1985 Jul 8;143(1):27-31. doi: 10.5694/j.1326-5377.1985.tb122764.x. Med J Aust. 1985. PMID: 3892256 Review.
-
Scintigraphic quantitation of gastrointestinal motor activity and transport: oesophagus and stomach.Eur J Nucl Med. 1992;19(9):815-23. doi: 10.1007/BF00182825. Eur J Nucl Med. 1992. PMID: 1396878 Review.