Abstract
An automated static perimeter/adaptometer is described which measures thresholds with lights of 2 wavelengths. The instrument uses light-emitting diodes to produce the stimuli and is controlled by a small computer, making it very suitable for clinical testing of large numbers of patients. The use of 2 LEDs with different peak emission wavelengths (530 and 660 nm) permits an assessment of the relative state of rod and cone mechanisms in a particular region of the retina either during dark adaptation or when the eye is fully dark adapted.
Similar articles
-
[Modification of an automated perimeter for dark- and light-adapted perimetry].Nippon Ganka Gakkai Zasshi. 1990 Dec;94(12):1162-8. Nippon Ganka Gakkai Zasshi. 1990. PMID: 2082736 Japanese.
-
Rod-cone interactions and analysis of retinal disease.Br J Ophthalmol. 1985 Jun;69(6):404-15. doi: 10.1136/bjo.69.6.404. Br J Ophthalmol. 1985. PMID: 3873959 Free PMC article.
-
Retinal cone dysfunction of supernormal rod ERG type. Five new cases.Acta Ophthalmol (Copenh). 1993 Apr;71(2):246-55. doi: 10.1111/j.1755-3768.1993.tb04998.x. Acta Ophthalmol (Copenh). 1993. PMID: 8333273
-
Rod-cone interaction in patients with fundus flavimaculatus.Br J Ophthalmol. 1987 Oct;71(10):762-5. doi: 10.1136/bjo.71.10.762. Br J Ophthalmol. 1987. PMID: 3676146 Free PMC article.
-
Recent advances in the dark adaptation investigations.Int J Ophthalmol. 2015 Dec 18;8(6):1245-52. doi: 10.3980/j.issn.2222-3959.2015.06.31. eCollection 2015. Int J Ophthalmol. 2015. PMID: 26682182 Free PMC article. Review.
Cited by
-
Rod and cone psychophysics and electroretinography: methods for comparison in retinal degenerations.Doc Ophthalmol. 1988 Jun;69(2):119-30. doi: 10.1007/BF00153692. Doc Ophthalmol. 1988. PMID: 3168714
-
A computer-controlled system for measuring dark adaptation and other psychophysical functions.Graefes Arch Clin Exp Ophthalmol. 1998 Jan;236(1):31-40. doi: 10.1007/s004170050039. Graefes Arch Clin Exp Ophthalmol. 1998. PMID: 9457514
-
Vitamin A treatment for night blindness in primary biliary cirrhosis.Br Med J (Clin Res Ed). 1984 Apr 7;288(6423):1030-1. doi: 10.1136/bmj.288.6423.1030. Br Med J (Clin Res Ed). 1984. PMID: 6423181 Free PMC article.
-
Abnormal dark adaptation kinetics in autosomal dominant sector retinitis pigmentosa due to rod opsin mutation.Br J Ophthalmol. 1992 Aug;76(8):465-9. doi: 10.1136/bjo.76.8.465. Br J Ophthalmol. 1992. PMID: 1390527 Free PMC article.
-
Autosomal dominant retinitis pigmentosa with apparent incomplete penetrance: a clinical, electrophysiological, psychophysical, and molecular genetic study.Br J Ophthalmol. 1993 Aug;77(8):473-9. doi: 10.1136/bjo.77.8.473. Br J Ophthalmol. 1993. PMID: 8025041 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical