In vivo and in vitro studies of the stress-corrosion cracking behavior of surgical implant alloys
- PMID: 6863350
- DOI: 10.1002/jbm.820170307
In vivo and in vitro studies of the stress-corrosion cracking behavior of surgical implant alloys
Abstract
Behavior of implant alloys exposed simultaneously to tensile stresses and corrosion environments has been examined. In the in vivo studies, a stainless steel and a titanium alloy exhibited cracklike features when loaded to the yield stress sigma y and implanted for 16 weeks. A cobalt-chromium alloy stressed beyond sigma y exhibited them in plastically deformed areas. A cobalt-chromium-nickel-molybdenum alloy appeared to be immune. In vitro samples loaded to various stress levels were immersed in Ringer's solution at 37 degrees C. Half of them were subjected to applied anodic potentials; the remaining control group was not. The applied potentials were dc potentials of magnitude similar to those generated by bioelectric effects. No attempt was made to duplicate time dependence or wave forms. Cracklike features were observed in the stainless steel and in the titanium alloy loaded to or beyond sigma y and polarized for 38 weeks. None were observed below sigma y. For the controls, no cracklike features were observed at any stress level after 53 1/2 weeks. Polarization measurements and potential versus time measurements were performed to study possible mechanisms for crack propagation. These investigations suggest that the in vivo corrosion environment is more severe than a 37 degrees C Ringer's solution because of the influence of both bioelectric effects and organic constituents. The implications of these studies for the performance of prosthetic devices is discussed.
Similar articles
-
The influence of static stress on the corrosion behavior of 316L stainless steel in Ringer's solution.J Biomed Mater Res. 1986 Apr;20(4):493-505. doi: 10.1002/jbm.820200406. J Biomed Mater Res. 1986. PMID: 3700443
-
Evaluation of a precipitation hardened wrought cobalt-nickel-chromium-titanium alloy for surgical implants.J Biomed Mater Res. 1978 Nov;12(6):805-21. doi: 10.1002/jbm.820120604. J Biomed Mater Res. 1978. PMID: 739014
-
Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?Spine J. 2004 Jul-Aug;4(4):379-87. doi: 10.1016/j.spinee.2003.12.004. Spine J. 2004. PMID: 15246296
-
[Biodeterioration and corrosion of metallic implants and prostheses].Medicina (B Aires). 1993;53(3):260-74. Medicina (B Aires). 1993. PMID: 8114635 Review. Spanish.
-
Podiatric metallurgy and the effects of implanted metals on living tissues.Clin Podiatry. 1985 Jan;2(1):121-41. Clin Podiatry. 1985. PMID: 3893811 Review.
Cited by
-
Effects of external stress on biodegradable orthopedic materials: A review.Bioact Mater. 2016 Sep 13;1(1):77-84. doi: 10.1016/j.bioactmat.2016.09.002. eCollection 2016 Sep. Bioact Mater. 2016. PMID: 29744397 Free PMC article. Review.
-
Corrosion of Metallic Biomaterials: A Review.Materials (Basel). 2019 Jan 28;12(3):407. doi: 10.3390/ma12030407. Materials (Basel). 2019. PMID: 30696087 Free PMC article. Review.
-
Fatigue Crack Growth and Fracture of Internal Fixation Materials in In Vivo Environments-A Review.Materials (Basel). 2021 Jan 1;14(1):176. doi: 10.3390/ma14010176. Materials (Basel). 2021. PMID: 33401437 Free PMC article. Review.
-
Does the novel artificial cervical joint complex resolve the conflict between stability and mobility after anterior cervical surgery? a finite element study.Front Bioeng Biotechnol. 2024 Jun 3;12:1400614. doi: 10.3389/fbioe.2024.1400614. eCollection 2024. Front Bioeng Biotechnol. 2024. PMID: 38887613 Free PMC article.
-
Electrical implications of corrosion for osseointegration of titanium implants.J Dent Res. 2011 Dec;90(12):1389-97. doi: 10.1177/0022034511408428. Epub 2011 May 9. J Dent Res. 2011. PMID: 21555775 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources