Quantitative histologic evaluation of LTI carbon, carbon-coated aluminum oxide and uncoated aluminum oxide dental implants
- PMID: 6863353
- DOI: 10.1002/jbm.820170311
Quantitative histologic evaluation of LTI carbon, carbon-coated aluminum oxide and uncoated aluminum oxide dental implants
Abstract
The response of mandibular bone to identical geometry LTI carbon, carbon-coated aluminum oxide, and uncoated aluminum oxide blade-type dental implants in baboons for 2 years was evaluated using histologic, microradiographic, and scanning electron microscopic methods. In addition, a quantitative histologic analysis was performed identifying the type, amount, and distribution of tissue surrounding the dental implant systems. This is the final phase of a study investigating the effect of implant elastic modulus and implant surface chemical composition on the performance of dental implants. Previous studies have utilized clinical and radiographic evaluations, postretrieval mechanical testing, and finite element stress analysis to evaluate the dental implant performance. The results of the histologic study revealed a direct implant-bone interface with no intervening soft tissue in 16 of the 21 implants (76%). A fibrous tissue interface was observed in 5 of 21 implants (24%). Quantitative histologic results for the implants with a direct implant-bone interface showed statistically larger crestal cortical plates (p less than 0.05) and greater area fraction crestal cancellous bone (p less than 0.05) in the LTI carbon implant compared to the carbon-coated and uncoated aluminum oxide implants. The carbon-coated and uncoated aluminum oxide implants demonstrated statistically greater area fraction cancellous bone at the inferior region of the implant (p less than 0.05) and thinned and reduced crestal cortical plates when compared to the LTI carbon implants. The results indicate that significant stress shielding of the crestal bone had occurred with the rigid carbon-coated and uncoated aluminum oxide implants when compared to the LTI carbon implants which had a material elastic modulus similar to cortical bone. Based upon the histologic results, it appears that the LTI carbon implants with the direct implant-bone interface exhibited a greater potential for long-term successful performance compared to the aluminum oxide substrate implants.
Similar articles
-
The retention mechanics of LTI carbon, carbon-coated aluminum oxide, and uncoated aluminum oxide dental implants.J Biomed Mater Res. 1983 Sep;17(5):873-83. doi: 10.1002/jbm.820170514. J Biomed Mater Res. 1983. PMID: 6352708
-
The influence of implant elastic modulus on the stress distribution around LTI carbon and aluminum oxide dental implants.J Biomed Mater Res. 1981 Nov;15(6):879-87. doi: 10.1002/jbm.820150612. J Biomed Mater Res. 1981. PMID: 7309769
-
Parameters affecting the stress distribution around LTI carbon and aluminum oxide dental implants.J Biomed Mater Res. 1982 Nov;16(6):875-85. doi: 10.1002/jbm.820160612. J Biomed Mater Res. 1982. PMID: 7174713
-
The long-term efficacy of currently used dental implants: a review and proposed criteria of success.Int J Oral Maxillofac Implants. 1986 Summer;1(1):11-25. Int J Oral Maxillofac Implants. 1986. PMID: 3527955 Review. No abstract available.
-
A new implant philosophy.J Prosthet Dent. 1980 Jan;43(1):71-7. doi: 10.1016/0022-3913(80)90356-x. J Prosthet Dent. 1980. PMID: 6985670 Review.
Cited by
-
Three-dimensional finite element analysis of the biomechanical properties of different material implants for replacing missing teeth.Odontology. 2025 Jan;113(1):80-88. doi: 10.1007/s10266-024-00942-0. Epub 2024 May 8. Odontology. 2025. PMID: 38717525
-
The improved biological performance of a novel low elastic modulus implant.PLoS One. 2013;8(2):e55015. doi: 10.1371/journal.pone.0055015. Epub 2013 Feb 21. PLoS One. 2013. PMID: 23437048 Free PMC article.
-
Biological and functional evaluation of a novel pyrolytic carbon implant for the treatment of focal osteochondral defects in the medial femoral condyle: assessment in a canine model.J Orthop Surg Res. 2016 Dec 1;11(1):155. doi: 10.1186/s13018-016-0488-5. J Orthop Surg Res. 2016. PMID: 27906096 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources