The estimation of bladder volume by sonocystography
- PMID: 6876269
- DOI: 10.1016/s0022-5347(17)51087-3
The estimation of bladder volume by sonocystography
Abstract
Real-time ultrasonography was used to measure bladder volumes. Volumes were calculated as the product of 3 internal bladder diameters (height, width and depth). The true bladder volume was obtained from the voided volume or by catheterization. There was a good correlation between calculated and true volumes provided a correction factor of 0.6 was applied. It also was found that a simpler method using only 2 diameters and a correction factor of 0.15 was nearly as reliable. The accuracy of this quantitative method was shown to be limited to an average error of plus or minus 25 per cent for bladder volumes between 100 and 500 ml. Smaller volumes could be assessed only qualitatively. False negative readings were common for bladder volumes less than 50 ml.
Similar articles
-
Transrectal ultrasound to measure bladder volumes in men.J Urol. 1990 Apr;143(4):687-9. doi: 10.1016/s0022-5347(17)40060-7. J Urol. 1990. PMID: 2179580
-
Residual urine determination by ultrasonic scanning.Am J Roentgenol Radium Ther Nucl Med. 1975 Oct;125(2):474-8. doi: 10.2214/ajr.125.2.474. Am J Roentgenol Radium Ther Nucl Med. 1975. PMID: 54004
-
Normal peak urinary flow rates obtained from small voided volumes can provide a reliable assessment of bladder function.J Urol. 1982 Mar;127(3):484-8. doi: 10.1016/s0022-5347(17)53877-x. J Urol. 1982. PMID: 6460877
-
[Urodynamic phenomena in the aging bladder].Urologe A. 2004 May;43(5):542-6. doi: 10.1007/s00120-004-0564-z. Urologe A. 2004. PMID: 15045179 Review. German.
-
On Diseases of the Bladder.Med Chir Rev. 1838 Jul 1;29(57):166-186. Med Chir Rev. 1838. PMID: 29918727 Free PMC article. Review. No abstract available.
Cited by
-
Postpartum urinary retention: what are the sequelae? A long-term study and review of the literature.Int Urogynecol J. 2022 Jun;33(6):1601-1608. doi: 10.1007/s00192-021-05074-5. Epub 2022 Feb 7. Int Urogynecol J. 2022. PMID: 35129645 Free PMC article. Review.
-
Ureteroscopy and cystoscopy training: comparison between transparent and non-transparent simulators.BMC Med Educ. 2015 Jun 2;15:93. doi: 10.1186/s12909-015-0380-8. BMC Med Educ. 2015. PMID: 26032174 Free PMC article. Clinical Trial.
-
Estimation of bladder wall location in ultrasound images.Med Biol Eng Comput. 1991 May;29(3):297-303. doi: 10.1007/BF02446712. Med Biol Eng Comput. 1991. PMID: 1943262
-
The accuracy of post-void residual measurement in women.Int Urogynecol J Pelvic Floor Dysfunct. 2008 May;19(5):603-6. doi: 10.1007/s00192-008-0568-0. Epub 2008 Feb 27. Int Urogynecol J Pelvic Floor Dysfunct. 2008. PMID: 18301853 No abstract available.
-
Evaluation of a 3-dimensional ultrasound device for noninvasive measurement of urinary bladder volume in dogs.J Vet Intern Med. 2020 Jul;34(4):1488-1495. doi: 10.1111/jvim.15811. Epub 2020 May 28. J Vet Intern Med. 2020. PMID: 32463540 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources