Dental implant fixation by electrically mediated process. I. Interfacial strength
- PMID: 687714
- DOI: 10.3109/10731197809118697
Dental implant fixation by electrically mediated process. I. Interfacial strength
Abstract
In order to determine the effect of electrical stimulation on canine alveolar bone, porous PMMA dental implants with a solid core (on which a Pt-13% Rh electrode was wound) were implanted in the mesial socket of the canine mandibular fourth premolars bilaterally. The positive electrode was implanted into the distal socket. The power pack was placed over the masseteric fossa. The implants, wires and power packs were all implanted subcutaneously. Each animal had an experimental and control implant. Mechanical push-out samples were prepared by sectioning a 2mm thick section of the mandible with the implant in the middle. The samples were tested immediately and the load-deflection curves were obtained.
Similar articles
-
Dental implant fixation by electrically mediated process. II. Tissue ingrowth.Biomater Med Devices Artif Organs. 1978;6(4):291-303. doi: 10.3109/10731197809119790. Biomater Med Devices Artif Organs. 1978. PMID: 749940
-
Evaluation of recombinant human osteogenic protein-1 (rhOP-1) placed with dental implants in fresh extraction sites.J Oral Implantol. 1995;21(4):281-9. J Oral Implantol. 1995. PMID: 8699520
-
Role of teeth adjacent to implants installed immediately into extraction sockets: an experimental study in the dog.Clin Oral Implants Res. 2012 Apr;23(4):402-8. doi: 10.1111/j.1600-0501.2011.02343.x. Epub 2011 Oct 20. Clin Oral Implants Res. 2012. PMID: 22092769
-
Some advances in endosseous implants.J Oral Rehabil. 1981 Jun;8(4):319-31. doi: 10.1111/j.1365-2842.1981.tb00506.x. J Oral Rehabil. 1981. PMID: 7024488 Review.
-
Predictability of Orthodontic Forced Eruption in Developing an Implant Site: A Systematic Review.J Clin Orthod. 2016 Aug;50(8):485-492. J Clin Orthod. 2016. PMID: 27710950 No abstract available.
Cited by
-
Smart Injectable Self-Setting Monetite Based Bioceramics for Orthopedic Applications.Materials (Basel). 2018 Jul 22;11(7):1258. doi: 10.3390/ma11071258. Materials (Basel). 2018. PMID: 30037147 Free PMC article.
-
Micro-morphologic changes around biophysically-stimulated titanium implants in ovariectomized rats.Head Face Med. 2007 Jul 16;3:28. doi: 10.1186/1746-160X-3-28. Head Face Med. 2007. PMID: 17634134 Free PMC article.
-
Preliminary studies on the effects of direct current on the bone/porous implant interfaces.Ann Biomed Eng. 1980;8(1):93-101. doi: 10.1007/BF02363173. Ann Biomed Eng. 1980. PMID: 7458021 No abstract available.