A preliminary investigation on the use of thermodilution and echocardiography as an assessment of cardiac function in the cat
- PMID: 6883182
- PMCID: PMC1235902
A preliminary investigation on the use of thermodilution and echocardiography as an assessment of cardiac function in the cat
Abstract
A technique for the determination of cardiac output in the cat by the thermal dilution method is described. The values of cardiac output assessed by thermal dilution and the values of left ventricular function assessed echocardiographically are compared. Values of cardiac output obtained by thermal dilution compare favourably with values obtained by other investigators by indicator dye dilution, the Fick method and electromagnetic flowmeter technique. The technique of thermal dilution in the cat was consistent and simple to perform. The calculation of ventricular volumes and cardiac output echocardiographically using formulae suggested in man was unsuccessful. Such formulae based on assumptions of cardiac shape and contractility do not appear valid in the cat. Statistical analysis demonstrated a positive correlation between the cardiac output determined by thermodilution and the left ventricular diastolic and systolic dimensions determined echocardiographically. A positive correlation was also shown between the cardiac output and the cardiac index, the left ventricular diastolic dimension and the left ventricular systolic dimension and the percent change in minor diameter and the velocity of circumferential fibre shortening. A negative correlation existed between the left ventricular systolic dimension and the velocity of circumferential fibre shortening and the ejection time and the velocity of circumferential fibre shortening.
Similar articles
-
Echocardiographic study of the anesthetized cat.Can J Comp Med. 1982 Apr;46(2):115-22. Can J Comp Med. 1982. PMID: 7093808 Free PMC article.
-
Comparison of three methods for cardiac output determination in cats.Am J Vet Res. 1985 Dec;46(12):2546-52. Am J Vet Res. 1985. PMID: 4083591
-
Echocardiographic assessment of cats anesthetized with xylazine-sodium pentobarbital.Can J Comp Med. 1983 Jul;47(3):281-3. Can J Comp Med. 1983. PMID: 6640411 Free PMC article.
-
Systolic time intervals and their derivatives for evaluation of cardiac function.J Vet Intern Med. 1992 Mar-Apr;6(2):55-63. doi: 10.1111/j.1939-1676.1992.tb03152.x. J Vet Intern Med. 1992. PMID: 1588542 Review.
-
Thermodilution method for measuring cardiac output.Eur Heart J. 1990 Dec;11 Suppl I:17-20. doi: 10.1093/eurheartj/11.suppl_i.17. Eur Heart J. 1990. PMID: 2092986 Review.
Cited by
-
Cardiopulmonary effects of a halothane/oxygen combination in hypovolemic cats.Can J Vet Res. 1988 Oct;52(4):428-33. Can J Vet Res. 1988. PMID: 3196972 Free PMC article.
-
Accuracy of thermodilution measurement of cardiac output in low flows applicable to feline and small canine patients.Can J Comp Med. 1984 Oct;48(4):425-7. Can J Comp Med. 1984. PMID: 6509371 Free PMC article.
-
Cardiopulmonary effects of a ketamine hydrochloride/acepromazine combination in healthy cats.Can J Vet Res. 1988 Jan;52(1):1-4. Can J Vet Res. 1988. PMID: 3127034 Free PMC article.
-
Correlation, agreement and concordance of cardiac output estimated by transthoracic ultrasound and transesophageal Doppler with pulmonary artery thermodilution in anesthetized cats.Vet Anaesth Analg. 2024 Nov-Dec;51(6):641-649. doi: 10.1016/j.vaa.2024.08.006. Epub 2024 Aug 14. Vet Anaesth Analg. 2024. PMID: 39244478 Free PMC article.
-
Evaluation of a xylazine-ketamine hydrochloride combination in the cat.Can J Vet Res. 1986 Jan;50(1):23-6. Can J Vet Res. 1986. PMID: 3742353 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous