Quantification of pressure gradients across stenotic valves by Doppler ultrasound
- PMID: 6886232
- DOI: 10.1016/s0735-1097(83)80311-8
Quantification of pressure gradients across stenotic valves by Doppler ultrasound
Abstract
Two-dimensional echocardiography has proven very useful in assessing valvular heart disease, but the technique is limited in certain groups of patients and is unable to quantify a transvalvular pressure gradient. Advances in the Doppler ultrasound techniques have made it possible to noninvasively measure velocity of flow across a stenotic heart valve and to calculate the pressure gradient. A commercially available, continuous and pulse wave Doppler instrument was utilized to assess the transvalvular pressure gradient in patients with mitral and aortic stenosis and the transmitral pressure half-time to calculate mitra valve area. Thirty-five consecutive adult patients with suspected aortic stenosis and 30 adult patients with suspected mitral stenosis underwent Doppler ultrasound examination within 24 hours of cardiac catheterization. An adequate Doppler examination was obtained in 81% of the patients with aortic stenosis, with a correlation between the Doppler-derived transaortic gradient and the catheterization-derived gradient of 0.94. The Doppler-measured gradient accurately separated those patients with significant aortic stenosis (gradients of greater than 50 mm Hg) from those patients with noncritical aortic stenosis. Similarly, an adequate Doppler examination was obtained in 90% of the adult patients with mitral stenosis. There was also close correlation between the mitral valve area and mean pressure gradient measured by the Doppler technique and that obtained at the time of cardiac catheterization (r = 0.87 and 0.85, respectively). The Doppler technique proved to be useful in those patients who had also undergone prior mitral commissurotomy. This study confirms that the combined continuous pulse wave Doppler technique will serve as a valuable addition to the diagnostic capabilities offered by echocardiography.
Similar articles
-
Comparative accuracy of two-dimensional echocardiography and Doppler pressure half-time methods in assessing severity of mitral stenosis in patients with and without prior commissurotomy.Circulation. 1986 Jan;73(1):100-7. doi: 10.1161/01.cir.73.1.100. Circulation. 1986. PMID: 3510084
-
Practical value of echo Doppler evaluation of aortic and mitral stenosis: a comparative study with cardiac catheterization.Henry Ford Hosp Med J. 1990;38(1):87-90. Henry Ford Hosp Med J. 1990. PMID: 2228721
-
[Comparison of pulsed and continuous Doppler techniques for the evaluation of left ventricular stenoses].Arch Mal Coeur Vaiss. 1985 Oct;78(10):1473-83. Arch Mal Coeur Vaiss. 1985. PMID: 3938213 French.
-
[Quantification of valvular stenosis by Doppler echography].Arch Mal Coeur Vaiss. 1990 May;83(6):839-52. Arch Mal Coeur Vaiss. 1990. PMID: 2114841 Review. French.
-
Assessment of valvular heart disease by Doppler echocardiography.Clin Cardiol. 1983 Dec;6(12):573-87. doi: 10.1002/clc.4960061202. Clin Cardiol. 1983. PMID: 6362941 Review.
Cited by
-
Clinical value of Doppler echocardiography in the assessment of adults with aortic stenosis.Br Heart J. 1985 Jun;53(6):636-9. doi: 10.1136/hrt.53.6.636. Br Heart J. 1985. PMID: 4005086 Free PMC article.
-
Hemodynamic Measurement Using Four-Dimensional Phase-Contrast MRI: Quantification of Hemodynamic Parameters and Clinical Applications.Korean J Radiol. 2016 Jul-Aug;17(4):445-62. doi: 10.3348/kjr.2016.17.4.445. Epub 2016 Jun 27. Korean J Radiol. 2016. PMID: 27390537 Free PMC article. Review.
-
Non-invasive estimation of the mean pressure difference in aortic stenosis by Doppler ultrasound.Br Heart J. 1986 Nov;56(5):450-4. doi: 10.1136/hrt.56.5.450. Br Heart J. 1986. PMID: 3539164 Free PMC article.
-
A comparison of the assessment of mitral valve area by continuous wave Doppler and by cross sectional echocardiography.Br Heart J. 1987 Apr;57(4):348-55. doi: 10.1136/hrt.57.4.348. Br Heart J. 1987. PMID: 3580222 Free PMC article.
-
Nonconvective forces: a critical and often ignored component in the echocardiographic assessment of transvalvular pressure gradients.Cardiol Res Pract. 2012;2012:383217. doi: 10.1155/2012/383217. Epub 2011 Oct 7. Cardiol Res Pract. 2012. PMID: 22007334 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources